DRAIN SYSTEM
ELECTRICAL REQUIREMENTS
n
A 220-240 volt, 50 Hz., AC only, 10-amp, fused electric supply is
required. A time-delay fuse or circuit breaker is recommended. It
is recommended that a separate circuit serving only this appliance
be provided.
n
After installation, access to mains plug or disconnection from
mains supply via a double-pole switch, must be ensured at all
times in order to ensure immediate deactivation of the washer
in case of emergency.
n
This washer is equipped with a power supply cord having an
earthing plug. The plug should be accessible for disconnection
from the supply.
n
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualied persons
in order to avoid a hazard.
Drain system can be installed using a oor drain, wall standpipe,
oor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 51 mm (2"). Minimum
carry-away capacity: 38 L (10 gal.) per minute. Top of standpipe
must be at least 990 mm (39") high; install no higher than
2.44 m (96") from bottom of washer.
Laundry tub drain system
990 mm
(39")
114 mm
(4,5")
990 mm
(39")
114 mm
(4,5")
Wall standpipe drain system
710 mm
(28")
See requirements for oor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834). Minimum siphon break: 710 mm (28") from bottom
of washer. Additional hoses may be needed.
.
.
114 mm
(4,5")
.
Loading ...