 49-6000121 Rev. 0
Installation Instructions
CONNECTIONS AND PIPING
The GeoSpring Solar system shall be connected to
WKHFRQQHFWLRQSLSLQJZLWKDƎ137WKUHDG%HIRUH
tightening the connection, check to make sure that
VHDOVDUHSRVLWLRQHGSURSHUO\8VHDWRUTXHZUHQFKWR
tighten the connection and do not exceed a torque
of 30 ft-lbs. Please refer to Thermal Expansion and
/RFDO,QVWDOODWLRQ5HJXODWLRQVHFWLRQVIRUDGGLWLRQDO
information. Only use pipes suited for use in sanitary
facilities and which can withstand temperatures of at
OHDVW)7KH*HR6SULQJ6RODUV\VWHPUHTXLUHV
the use of all copper or brass fittings in the collector
loop plumbing. Couplings rather than unions should
be used to join the collectors to avoid leaks and fluid
ORVV8VHRQO\OHDGIUHHVROGHUNOTE: The piping
supports must not compress the insulation. If this is
not possible, insulate the piping supports as well. To
prevent dielectric corrosion, make sure that there
is no connection between stainless or galvanized
steel pipes and copper pipes.
COLLECTOR LOOP PIPE
INSULATION
The collector loop cold water supply and hot return
lines shall be well insulated with high quality flexible
FORVHGFHOOLQVXODWLRQWRPLQLPL]HKHDWORVV8VH
closed-cell tube insulation with a wall thickness of
ƎLQPLOGFOLPDWHV,QFROGFOLPDWHVZKHUHIUHH]LQJ
RFFXUVXVHLQVXODWLRQZLWKƎZDOOWKLFNQHVV
Any above ground exterior pipe insulation is subject
WR89GHJUDGDWLRQDQGPXVWEHMDFNHWHGZUDSSHG
with aluminum foil tape, or painted with two coats
of high quality water-based acrylic resin coating
as supplied by the insulation manufacturer. To the
extent possible, slide the insulation material over the
pipe without cutting or taping. Seal all butt joints with
contact adhesive. Do not use rigid polyethylene pipe
insulation. Insulate the pipes with a suitable material
of appropriate thickness in order to reduce heat loss
and protect the pipes from freezing. Do not insulate
the valves.
INCLINATION OF THE GEOSPRING
SOLAR SYSTEM
8VHWKH*HR6SULQJ6RODUV\VWHPRQO\LILWFDQEH
LQVWDOOHGVRWKDWLWKDVDQLQFOLQDWLRQRIDWOHDVW
EXWQRPRUHWKDQ3URWHFWWKHV\VWHPFRQQHFWLRQV
from contaminants entering the system, like dust etc.
INSTALLATION INSTRUCTIONS