Scotsman Cu0715

User Manual - Page 13

For CU0715.

PDF File Manual, 17 pages, Read Online | Download pdf file

CU0715 photo
Loading ...
Loading ...
Loading ...
User Manual for Models CU0415, CU0715 and CU0920
July 2013
Page 12
Maintenance
Regularly vacuum the right side of the air cooled
condenser with a brush to remove all loose dust and
dirt. Be careful not to damage the ns.
Cubed ice machines of this type make ice that is
more pure than the water supplied to it. Since the ice
has fewer impurities, the water that remains in the
reservoir has more. The water system dilutes that
concentration but eventually it does build up and need
to be removed. Over the years it has been determined
that the typical scale removal frequency is about 2
times per year.
To remove scale from the water system.
Materials needed:
Food grade, nickel safe scale remover for ice
machines, also known as ice machine cleaner.
Sanitizer
Hand tools.
Clean bucket
Clean cloths
Rubber or plastic gloves
1. Remove front panel.
2. Move master switch to Off, wait a minute and then
move it to On.
3. When the freeze cycle begins (blue light on),
switch the machine to Off.
4. Remove and discard the ice.
5. Drain reservoir by pulling drain plug and return
drain plug to its original position.
6. Mix a solution of 5 oz or 150 cc of Scotsman Clear
1 Scale Remover and 2.5 quarts or 2.4 liters of
clean, warm (95
o
F/35
o
C to 115
o
F./46
o
C) water.
7. Pour the solution into the reservoir by carefully
adding it at the reservoir’s front lip.
8. Move the master switch to the Wash position.
9. Wait 10 minutes.
10. Move the master switch to the Off position.
11. Drain the reservoir by removing drain plug and
draining the solution into the bin. Return the drain
plug to its normal position.
12. Remove spray platform by removing cube chute
and lifting spray platform up and off its connection.
If needed open platform and conrm all jets are
open. Rinse out any debris, reclose and return it
and the cube chute to the unit. Be sure gasket is
positioned correctly - narrow side faces up toward
jets.
13. Pour 2.5 quarts or 2.4 liters of warm (95
o
F/35
o
C to
115
o
F./46
o
C) water into the reservoir by adding it
at the reservoirs’ front lip.
14. Switch the master switch to Wash for 1 minute,
then switch it to Off.
15. Repeat step 11. Go to the next process to sanitize
the machine.
Sanitize Water System – after completing prior scale
removal and stopping at the end of its steps.
1. Mix a 1 gallon or 4 liter solution of locally
approved sanitizer and clean, warm (95
o
F/35
o
C
to 115
o
F./46
o
C) water. Use an EPA approved
food equipment sanitizer at the solution mix
recommended by the sanitizer manufacturer.
2. Pour about half of the sanitizer mix into the
reservoir.
3. Remove the cube chute and spray platforms and
wash them with the sanitizer, then return them to
the ice machine.
4. Move the master switch to the Wash position.
5. Circulate the sanitizer for 2 minutes.
6. Move the master switch to Off.
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner comes
in contact with skin, ush with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.
Loading ...
Loading ...
Loading ...