44
Maximum Connected Load For Deluxe Series (2500 and 3500)
The maximum connected load of a Zoneline unit occurs when the unit is in resistance heating operation. The maximum
amperage shown in the tables below is the combined total of the resistance heater and the indoor fan motor.
Model 230 V 208 V
Number Watts Amps Watts Amps
AZ25E07D2* 2600 11.4 2130 10.2
AZ25E07D3* 3500 15.3 2860 13.8
AZ25E09D2* 2610 11.4 2140 10.3
AZ25E09D3* 3510 15.3 2870 13.9
AZ25E09D5* 5060 22.0 4140 20.0
AZ25E12D2* 2620 11.5 2150 10.3
AZ25E12D3* 3520 15.4 2880 13.9
AZ25E12D5* 5070 22.1 4150 20.0
AZ25E15D2* 2630 11.5 2160 10.4
AZ25E15D3* 3520 15.4 2890 14.0
AZ25E15D5* 5080 22.1 4160 20.1
AZ35H07D2* 2600 11.4 2130 10.2
AZ35H07D3* 3500 15.3 2860 13.8
AZ35H09D2* 2610 11.4 2140 10.3
AZ35H09D3* 3510 15.3 2870 13.9
AZ35H09D5* 5060 22.0 4140 20.0
AZ35H12D2* 2620 11.5 2150 10.3
AZ35H12D3* 3510 15.4 2880 13.9
AZ35H12D5* 5070 22.1 4150 20.0
AZ35H15D2* 2630 11.5 2160 10.4
AZ35H15D3* 3530 15.4 2890 14.0
AZ35H15D5* 5080 22.1 4160 20.1
Model 265 V
Number Watts Amps
AZ25E07E3* 2600 9.8
AZ25E07E4* 3750 14.3
AZ25E09E3* 2610 9.9
AZ25E09E4* 3760 14.3
AZ25E09E5* 5060 19.2
AZ25E12E3* 2620 9.9
AZ25E12E4* 3770 14.3
AZ25E12E5* 5070 19.2
AZ25E15E3* 2630 9.9
AZ25E15E4* 3780 14.3
AZ25E15E5* 5080 19.2
AZ35H07E3* 2600 9.8
AZ35H07E4* 3750 14.3
AZ35H09E3* 2610 9.9
AZ35H09E4* 3760 14.3
AZ35H09E5* 5060 19.2
AZ35H12E3* 2620 9.9
AZ35H12E4* 3770 14.3
AZ35H12E5* 5070 19.2
AZ35H15E3* 2630 9.9
AZ35H15E4* 3780 14.3
AZ35H15E5* 5080 19.2
Maximum Connected Load For Premium Series (5500) 230/208 V
Model With RAK3152 With RAK3202 With RAK3302
Number Watts/Amps Watts/Amps Watts/Amps
230V 208V 230V 208V 230V 208V
AZ55H07DA* 2615/11.4 2145/10.3 3515/15.3 2880/13.9 3515/15.3** 2880/13.9**
AZ55H09DA* 2615/11.4 2145/10.3 3515/15.3 2880/13.9 5065/22.0 4150/20.0
AZ55H12DA* 2640/11.5 2165/10.4 3540/15.4 2900/14.0 5090/22.1 4170/20.1
AZ55H15DA* 2685/11.7 2210/10.6 3585/15.6 2945/14.2 5135/22.3 4215/20.3
Maximum Connected Load For Premium Series (5500) 265V
Model With RAK5152*** With RAK5172 With RAK5202 With RAK5302
Number Watts/Amps Watts/Amps Watts/Amps Watts/Amps
AZ55H07EA* 2235/8.6 3075/11.6 3775/14.3 3775/14.3**
AZ55H09EA* 2400/9.1 3075/11.6 3775/14.3 5075/19.2
AZ55H12EA* 2670/10.3 3100/11.7 3800/14.4 5100/19.3
AZ55H15EA* 2965/11.4 3135/11.8 3835/14.5 5135/19.4
* Covers all model versions.
** AZ55H07 does not have 5 kW heater.
*** Maximum connected load occurs when this unit with this power connection kit is in simultaneous
operation of heat pump with supplemental 1700 watt heater.