Jenn-Air UXT4130ADS

User Manual - Page 8

For UXT4130ADS.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
8
5. Mark hole locations
Lift the range hood into place and insert the mounting bracket
tabs through the slots in the back of the range hood.
Hold the range hood rmly in place with one hand and
bendeach mounting tab (A) upward approximately 90°.
OPTIONAL: Mark the hole in each mounting tab.
Mark the hole at the power supply knockout (B).
For a non-vented (recirculating) installation: Go to Step 7.
For a top vented installation: Mark the 4 vent hole
locations(C)on the top of the range hood.
For a rear vented installation: Mark the 4 vent hole
locations(D) on the rear of the range hood.
OPTIONAL: Mark the hole in each mounting tab.
Remove the range hood and set it aside.
6. Mark and cut vent opening
3
1
/
4
" x 10" (8.3 x 25.4 cm) Rectangular Vent System
Using a 1/2" (13 mm) drill bit, drill a hole in each of the dots
marked previously on either the wall or upper cabinet. Using
the outside edges of the holes, mark the vent opening.
Using a jigsaw or keyhole saw, cut the vent opening.
7. Drill electrical opening
Using a 1
1
/
4
" (3 cm) drill bit, drill the hole in the dot
markedpreviously at the electrical strain relief.
OPTIONAL: Using a 1/8" (3 mm) drill bit, drill pilot holes
for thedots marked previously at each mounting tab
atanapproximate 45° angle in an upward direction.
45˚+
A
B
C
C
D
D
A
90˚
Loading ...
Loading ...
Loading ...