CLEANING & MAINTENANCE
This is a graphic
representation of lters
01. Front cover lock
02. LED indicator panel
03. Storage tank
04. Tap
05. Sediment lter
06. Inlet water tube
07. Diverter
08. Ball valve
1. After installation and GKK change, discard 5L~10L ( 3-5 mins) before you start using
your purier.
2. If you are out of home, switch-o the purier and turn-o the Ball Valve.
3. Ensure the input water temperature is between 10°C and 40°C. Do not connect the
purier to any geyser, heater etc.
4. Ensure that the area around and beneath the purier is kept clean at all the time.
Ensure that this area is free of ants/insects/other pests.
5. Don’t drop any of the components, or the purier as a whole from a height. This may
cause the components to fracture or break.
6. Do not allow any foreign or unexpected material (like dust/ants/insects/other pests)
to enter into the storage tank. The ltered water in the storage tank may deteriorate
in the process.
7. You can discard the water in the storage tank once in 15 days. Always drain the water
in the storage tank if you have not used the purier for more than 2 days.
1. The purier should be installed by a trained Pureit technician.
2. Pureit Marvella UV G2 has to be installed on the wall. In case you are using it in a table
top condition, please either place its back touching fully on wall or otherwise hold it
when you are operating any switch.
3. Do not install the purication unit where it could freeze.
4. Do not use an extension cord.
5. Please ensure that the purier is not installed near a cooking range.
6. Do not install the purier above an electric socket.
7. Avoid sharp bends to the tube that is connected to the purier.
8. Install the purier away from the sunlight.
INSTALLING YOUR PUREIT MARVELLA UV G2
TAKING CARE OF PUREIT MARVELLA UV G2
1
2
3
KEEP YOURSELF SAFE
4
1. Do not plug or unplug the power cord with wet hands. Ensure the plug isn’t wet while
plugging in, or plugging out to avoid risks such as electrical shocks or re. Plug the
power cord in the right size socket to avoid sparks.
2. Do not try to open the purier for any reason. This can be done only by the qualied
company personnel or authorized agent.
3. If the power cord is damaged, it must be replaced and not used.
4. Do not light candles / diya on the purier. Do not keep heavy or sharp objects, e.g.
Radio etc. on the purier.
5. In case you notice any smoke or burning smell from your purier, please switch o the
power, unplug the cord, turn-o Ball Valve and call us at 1860-210-1000.
6. Please dispose the used consumables like the Germkill Kit along with the other
household waste through the municipal disposal system.
7. Do not use water not intended for drinking in Pureit System e.g. from abandoned or
abused water bodies or water resources in which human, animal or industrial wastes
are disposed or water that is extremely acidic or alkaline.
8. The output water may continue to have ora which is harmless and pose no health
hazard to the normal healthy adults and children.
9. Always rely on the device alert system to change the Germkill Kit (GKK). Auto Shut-o is
the only additional assurance of safety.
10. Never buy Marvella UV G2 or the Germkill Kit (GKK) or spares from an unauthorized
source. Always call on 1800-210-1000 and we will deliver and install a new GKK at your
home.
•
P
U
R
E
I
T
C
U
S
T
O
M
E
R
C
A
R
E
N
O
•
KNOW YOUR PUREIT MARVELLA UV G2
PUREIT MARVELLA UV G2’S UNIQUE TECHNOLOGY
1. Sediment Filter (SF) (Raw Water Processor)
Removes ne and coarse particulate impurities/ dirt and improves life of the Carbon Filter.
2. Activated Carbon Filter
Removes chlorine and organic impurities like harmful pesticides. It also adsorbs bad taste
and odour-causing organic compounds from water.
3. Mesh Filter
Ensures that no suspended/dirt particles enter the UV chamber.
4. High Intensity UV Chamber
High intensity UV rays ensure maximum UV intensity for inactivation of bacteria, virus and
parasites to deliver safe water always.
1. You can clean the device by using disinfectants like bleach/hypochlorite ( 50 ppm
available chlorine ). Discard 2 litres of water after cleaning the tap.
2. External portion of the purier must be cleaned using wet cloth only. Do not use any
detergent or soap.
Rotate the housing clock-wise and
remove it completely from the cap
Take out the Sediment Filter
from the housing
Clean the Sediment
Filter under jet of water.
rub by hand / tap gently
to clean.
After cleaning the
lter, put it back in
the housing.
Insert the housing inside the cap & rotate
it anticlockwise to engage the threads.
Ensure the housing is tightened till it’s
original marking.
SF (Sediment Filter)
ATTENTION
• Close the ball valve before opening SF housing for cleaning.
• The housing needs to be opened in wall mounted position only.
• Make sure the clamp is properly xed on the wall & cap of housing.
• Keep the cap mounted on the wall. No need to remove the same.
• Please do not use any abrasive / pointed tool to clean the Sediment
Filter as it may damage the Sediment Filter.
• In case you observe the rubber ring is dirty, clean the rubber ring &
x it on the housing again properly.
• Clean the inner portion of the housing as well.
• If required, a Spanner for opening ESF housing can be bought from
Pureit service technician.
UNIQUE FEATURES OF PUREIT MARVELLA UV G2
* Based on 10 litres of water consumption per day.
4
3
2
1
Disposal Guidelines (Electrical): To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate electrical items in this product such as power supply adaptor, control circuits, LED
panel, and wiring from other types of waste and recycle them responsibly to promote sustainable use of material
resources. Contact either the retailer where you purchased this product, or local government oce for details of
where and how these items can be taken for environmentally safe recycling.
2
4
3
1
6
7
8
5
High Intensity UV Lamp
Powerful 11 W UV lamp for enhanced safety.
Advanced 4-stage Purication
Advanced 4-stage purication that ensures that every drop of water
from your Marvella UV G2 is pure & safe to drink.
4 Liters storage capacity
Ready to serve even in the absence of electricity.
Double Purity Lock
Advance Alert System warns you 15 days* in advance when your
purier will stop working.
Auto Shut o stops water ow when GKK life expires.
USEPA standards on Purication
Meets stringent criteria of Environmental Protection Agency,
EPA (USA) for harmful virus and bacteria removal.
Tank Full indicator
Indicates when the storage tank is full.
Compact, Sleek and Covered design
Optimises space and looks good in modern kitchen.
Fully automatic
Works without any intervention. The system senses if the water tank is
not full, puries and stores water automatically.
No AMC
Lower cost of maintenance.
Advanced Voltage Fluctuation Guard
Protects your purier from sudden voltage uctuation ranging between
110 and 270 Volts.
Break resistant tap
Equipped with break resistant tap which is tested for up to 50000 operations.