TROUBLESHOOTING
Condition/Problem Things to Check Solution
Console will not power up/
turn on/start
Batteries Make sure batteries are installed correctly. If batteries are
correctly installed, replace with a set of new batteries.
Check data cable integrity All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Make sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or
otherwise damaged. Replace Console if damaged.
If the above steps do not resolve the problem, contact your
local Schwinn
™
distributor.
Speed displayed is not
accurate
Display set to wrong unit
ofmeasure.(English/
Metric)
Changedisplayunits(consult“ConsoleServiceMode”)
Speed displayed is always
“0”/stuckinPausemode
Data cable Make sure the data cable is connected to the back of the
Console and the main frame assembly.
SpeedSensor(under
Shrouds)
Make sure the Speed Sensor Magnet and the Speed Sensor
are in place.
No speed/RPM reading Check data cable integrity All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check Speed Sensor
Magnetposition(requires
shroudremoval)
Magnet should be in place on pulley.
Check Speed Sensor As-
sembly(requiresshroud
removal)
Speed Sensor Assembly should be aligned with magnet and
connected to data cable. Realign sensor if necessary. Replace
if there is any damage to the sensor or the connecting wire.
Consoledisplays“Lbatt”
error code
Batteries Replace batteries
Unit operates but Tele-
metric Heart Rate not
displayed
ChestStrap(optional) Strap should be “POLAR
™
”compatibleanduncoded.Make
sure strap is directly against skin and contact area is wet.
Chest Strap Batteries If strap has replaceable batteries, install new batteries.
Interference Trymovingunitawayfromsourcesofinterference(TV,Micro-
wave,etc).
Replace Chest Strap If interference is eliminated and HR does not function, replace
strap.
Replace Console If HR still does not function, replace Console.
Consoleshutsoff(enters
sleepmode)whileinuse
Check data cable integrity All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into
place.
Check Speed Sensor
Magnetposition(requires
shroudremoval)
Speed Sensor Magnet should be in place on pulley.
Check Speed Sensor As-
sembly
Contact your local Schwinn
™
distributor.