Miele 09775910 36" Black Built-In Induction Electric Cooktop KM6370

User Manual - Page 58

For 09775910.

PDF File Manual, 76 pages, Read Online | Download pdf file

09775910 photo
Loading ...
Loading ...
Loading ...
Ventilation
58
a
Front
b
Ventilation cut-out in the rear wall of the base unit
(Slight) ventil
ation also takes place when the base unit is directly against the
wall.
c
Protective base
The in
stallation of a protective base beneath the cooktop is not required, but
permitted.
If a protective base is installed, the distance between the top edge of the coun‐
tertop and the top edge of the base must be at least 5¹/₈" (130 mm) for proper
ventilation of the cooktop.
Leave an air gap of 3" (75 mm) at the back for the power cord.
Cooktop Dimensions of the ventilation cutout
KM 6360 / KM 6365 24¹/₂" x 3" (622 x 75 mm)
KM 6370 / KM 6375 30" x 3" (762 x 75 mm)
KM 6377 35¹/₂" x 3" (902 x 75 mm)