User Manual - Page 152

For TRX420FA2 E 2019.

Loading ...
Loading ...
Loading ...
Servicing Your Honda
142
Rear Final Gear Oil
5.
Remove the oil level check bolt (3) and sealing washer (4).
6.
Slowly fill the rear final gear with the recommended oil until oil
start to flow out of the oil level check hole (5). Allow oil to settle
for 2 – 3 minutes before moving to next step to prevent overfilling.
85 cm
3
(2.9 US oz , 3.0 Imp oz)
7.
Coat a new O-ring with grease and install it into the fill cap
groove and tighten it to the specified torque:
12 N·m (1.2 kgf·m , 9 lbf·ft)
8.
Install the oil level check bolt with a new sealing washer and
tighten it to the specified torque:
12 N·m (1.2 kgf·m , 9 lbf·ft)
9.
Pour the drained oil into a suitable container and dispose of it in
an approved manner (page 210).
NOTICE
Improper disposal of drained fluids is harmful to the environment.
(5)
(3)
(3) oil level check bolt
(4) sealing washer
REAR
(4)
(5) oil level check hole
19 TRX420FA2 (ED)-32HR3B500.book 142 ペー 2018年4月23日 月曜日 午後6時3分