Loading ...
Loading ...
Loading ...
5
7 EXHAUST CONNECTION
8 LEVELING DRYER
Installation Instructions
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
STANDARD REAR EXHAUST
This dryer must be exhausted to the outdoors.
Use only metal duct.
Do not terminate exhaust in a chimney, any gas vent,
under an enclosed floor (crawl space), or into an attic.
The accumulated lint could create a fire hazard.
Provide an access for inspection and cleaning of the
exhaust system, especially at turns. Inspect and clean at
least once a year.
Never terminate the exhaust into a common duct with a
kitchen exhaust. A combination of lint and grease could
create a fire hazard.
Do not obstruct incoming or exhausted air.
THIS DRYER COMES READY FOR REAR EXHAUSTING. IF
SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION
12 TO EXHAUST DIRECTLY FROM THE LEFT SIDE OR
BOTTOM OF THE CABINET.
WE RECOMMEND THAT YOU INSTALL YOUR DRYER
BEFORE YOUR WASHER. THIS WILL PERMIT DIRECT
ACCESS FOR EASIER EXHAUST CONNECTION
WE STRONGLY RECOMMEND THE USE OF
RIGID METAL EXHAUST DUCT. IF USING
FLEXABLE METAL DUCT, CUT IT TO THE PROPER
LENGTH AND AVOID BUNCHING OF THE DUCT
BEHIND THE DRYER.
FOR STRAIGHT
LINE INSTALLATION,
CONNECT THE
DRYER EXHAUST
TO THE WALL USING
DUCT TAPE.
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.
ELBOW HIGHLY
RECOMMENDED.
ELBOW HIGHLY
RECOMMENDED.
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
LEVEL
SIDE-TO-SIDE.
4 LEVELING LEGS
2 ANTI-TIP LEGS
LEVEL
FRONT-TO-BACK.
STAND THE DRYER UPRIGHT NEAR THE
FINAL LOCATION AND ADJUST THE 4 LEVELING
LEGS TO MATCH THE HEIGHT OF YOUR WASHER.
ADJUST THE 2 ANTI-TIP LEGS TO CONTACT
THE FLOOR.
Loading ...
Loading ...
Loading ...