Bertazzoni MAST304GASXV 30 Inch Gas Range

User Manual - Page 8

For MAST304GASXV.

PDF File Manual, 23 pages, Read Online | Download pdf file

MAST304GASXV photo
Loading ...
Loading ...
Loading ...
8
/ Specifi cations
Burner
Auxiliary
Semi-rapid
Rapid
Dual burner
MAIN oven
30’’/48’
Broiler
30’’/48’
Oven 36’’
Broiler 36’’
AUX. Oven
48’’
Injector
diam.[mm]
0.90
0.54
1.18
0.70
1.55
0.92
0.80+2.10
0.50+1.20
1.85
1.10
1.40
0.98
2.00
1.16
1.60
0.98
1.25
0.75
Gas
Type
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
Pressure
[iwc]
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’
Max Rate
[Btu/hr]
3,500
3,300
5,900
5,500
10,400
9,500
19,000
19,000
14,000
14,500
9,000
10,500
17,000
15,000
11,000
11,000
7,000
7,000
Min Rate
[Btu/hr]
900
900
1,500
1,500
2,500
2,500
1,300
1,300
3,500
3,500
only max
only max
4,100
4,100
only max
only max
2,400
2,400
[W]
1,025
967
1,729
1,611
3,047
2,783
5,567
5,567
4,102
4,248
2,637
3,076
4,981
4,395
3,223
3,223
2,051
2,051
[W]
264
264
439
439
732
732
381
381
1,025
1,025
only max
only max
1,201
1,201
only max
only max
703
703
By-pass
diam.[mm]
Regulated
0.29
Regulated
0.36
Regulated
0.47
Regulated
0.34/0.65
Regulated
0.60
No by-pass
No by-pass
Regulated
0.62
No by-pass
No by-pass
Regulated
0.49
See use and care manual for the layout of the surface burners of your range
B
urner In
j
ector
G
a
s
Pre
ss
ure Max Rate Min Rate
By
-pas
s
Loading ...
Loading ...
Loading ...