Switching the appliance on and o
Switching the appliance on
Press the On/O button until the temperature display
lights up.
Switching the appliance o
Keep the On/O button pressed for approx. 3 seconds so that
the temperature display goes out.
Operating and control elements
The electronic control panel has the "touch capacitance tech-
nology".
Any function can be activated by touching the corresponding icon.
The exact contact point is
between the symbol and its label
1
Upper compartment temperature display
2
Lower compartment temperature display
3
Upper compartment temperature setting buttons
4
Lower compartment temperature setting buttons
5
On/O button (switching the appliance on and off)
6
Audible warning On/O button
7
Fan switch
8
Interior light On/O button
Symbols in the display
Alarm (symbol flashes if the temperature inside the appli-
ance is too high or too low)
Demo mode is activated
Setup mode is activated (activating the child lock and
adjusting the display brightness
The interior fan runs constantly
Child lock is activated
The interior light is switched on constantly
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase
current) or energy-saving plugs. Risk of dam-
age to the electronic control system!
Setting up
Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
The floor on which the appliance stands should be horizontal
and level.Compensate for uneven floors with the adjustable feet.
Do not cover ventilation openings
or grille.
Standard EN 378 specifies that the room in
which you install your appliance must have a
volume of 1 m
3
per 8 g of R 600a refrigerant
used in the appliance, so as to avoid the forma-
tion of inflammable gas/air mixtures in the room
where the appliance is located in the event of
a leak in the refrigerant circuit. The quantity of
refrigerant used in your appliance is indicated
on the type plate on the inside of the appliance.
Always install the appliance directly against
the wall.
Place the appliance in its final position
at the place of installation.
Extend the adjustable foot at the bottom
hinge bracket until it rests on the floor
and then make a further 90° turn.