Wolf ICBOG42 107cm Built-in Outdoor Natural Gas Grill

User Manual - Page 5

For ICBOG42.

PDF File Manual, 13 pages, Download pdf file

Loading ...
Loading ...
Loading ...
wolfappliance.com
|
5
SPECIFICATIONS
Gas Supply
The outdoor grill must be connected to a regulated gas
supply. The supply line must be equipped with an approved
external gas shut-off valve located near the grill in an
acces-sible location. Do not block access to the shut-off
valve. Refer to the illustration below.
A gas supply line of 19 mm rigid pipe must be provided to
the outdoor grill or module. If local codes permit, a certi-
fied, .9 m long, 13 mm or 19 mm ID flexible metal appliance
connector is recommended to connect the units
1
/2" NPT
(or ISO 7/1-14) female inlet to the gas supply line. Pipe joint
compounds suitable for use with natural or LP gas should
be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of
100mbar. The appliance must be isolated from the gas
supply piping system by closing its individual manual shut-off
valve during a
ny pressure testing of the system at test
pressures equal to or less than 100 mbar.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLYTO APPLIANCE
Gas shut-off valve.
GAS RATING
MODEL
TOTAL
HEAT INPUT
GAS
UNITS
APPLIANCE
CATEGORY
TYPES/PRESSURE
(mbar) COUNTRY OF DESTINATION
ICBOG30 18.8 kW 12H G20 at 20 AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV,
LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
12E G20 at 20 DE, LU, PL
12E+ G20 at 20/25 BE, FR
ICBOG30-LP 18.8 (1344) kW (g/h) 13P G31 at 37 FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
ICBOG36 26.1 kW 12H G20 at 20 AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV,
LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
12E G20 at 20 DE, LU, PL
12E+ G20 at 20/25 BE, FR
ICBOG36-LP 26.1 (1865) kW (g/h) 13P G31 at 37 FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
ICBOG42 26.7 kW 12H G20 at 20 AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV,
LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
12E G20 at 20 DE, LU, PL
12E+ G20 at 20/25 BE, FR
ICBOG42-LP 26.7 (1908) kW (g/h) 13P G31 at 37 FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
ICBOG54 37.5 kW 12H G20 at 20 AT, BG, CR, CZ, DK, EE, FI, GR, HR, HU, IS, IE, IT, LV,
LT, NO, PT, RO, SK, SI, ES, SE, CH, TR, GB
12E G20 at 20 DE, LU, PL
12E+ G20 at 20/25 BE, FR
ICBOG54-LP 37.5 (2680) kW (g/h) 13P G31 at 37 FI, CR, GR, IE, HR, LU, NL, PL, SK, SI, ES, CH, TR, GB
A
ustralia Only
Inlet thread connection detail
· Burner manifold inlet – ½” BSP
· RV47 regulator – ½” BSP
·
RV48 regulator – ¾” BSP
(54” grill)
LP hose assembly connection to
manifold – 3/8” SAE flare with 5/8-18
UNF (and BSP adaptor)
Loading ...
Loading ...
Loading ...