Scotsman N0422e N0422-E

User Manual - Page 10

For N0422-E.

PDF File Manual, 24 pages, Download pdf file

Loading ...
Loading ...
Loading ...
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
E Series Air, Water or Remote User Manual
January 2017
Page 9
Remote condenser models have additional installation
needs.
The correct remote condenser fan and coil must
be connected to the ice making head. Liquid and
discharge tubing connections are on the back of
the ice machine cabinet. Tubing kits are available in
several lengths to accommodate most installations.
Order the one that just exceeds the length needed for
the installation.
The kit numbers are:
BRTE10
BRTE25
BRTE40
BRTE75
There are limits as to how far away from the ice
machine and where the remote condenser can be
located. See page 10 for those limits.
The correct condenser must be used.
Ice Machine
Model
Voltage Condenser
Model
F0822R,
N0622R
115 ERC111-1
F1222R,
N0922R
208-230 ERC311-32
N1322R 208-230 ERC311-32
Do not reuse condenser coils contaminated with
mineral oil (used with R-502 for example). They will
cause compressor failure and will void the warranty.
A headmaster is required for all remote condenser
systems. Prior condensers did not have a
headmaster. New head / prior condenser retrots can
use headmaster kit KPFHM.
Use of non-Scotsman condensers requires pre-
approval from Scotsman Engineering.
Refrigeration - Remote Condenser Models
Ground
Wire
Connection
Black
White
Ground
Power
Supply
Wires
Install
Strain
Relief
Junction
Box
Cover
To Remote
Condenser
Fan Motor
Blue
Ground
Wire
Connection
Black
White
Ground
Power
Supply
Wires
Install
Strain
Relief
Install
Strain
Relief
Junction
Box
Cover
Loading ...
Loading ...
Loading ...