TECHNICAL DATA
P16HP
P18HP
Capacity
Cooling
4.6 kWh
16,000 BTU
5.2 kWh
18,000 BTU
Heating
4.2 kWh
14,000 BTU
4.7 kWh
16,000 BTU
Rated Input
Cooling
1769W
2000W
Heating
1826W
2043W
Running Current
Cooling
8.0 Amps
9.3 Amps
Heating
8.4 Amps
9.4 Amps
Noise (sound power)
<65dB(A)
<65dB(A)
Permitted Excessive
Operating Pressure
1.0/2.6MPa
1.0/2.6MPa
Maximum Allowable
Pressure
1.2/3.2Mpa
1.2/3.2Mpa
Power Supply
220-240V/50Hz
220-240V/50Hz
Net Weight
29 kgs
30 kgs
Refrigerant Quantity
225g
300g
Dimensions
(L*D*H)
470*370*764 mm
470*370*764 mm
Unit must be vented outside when in Air Cooling and
Heating mode.
For the purposes of EU regulation EN12102 this is a local
air conditioner and produces less than 65dB(A) sound
energy.