Water
Water Supply, all models: The recommended water
supply tubing is ¼ inch OD copper. Stainless steel
flex or reinforced PVC tube may also be used.
Install an easily accessible shut-off valve between
the supply and the unit. This shut-off valve should
not be installed behind the unit.
Note: Do not use self-piercing type valves.
1. Remove the front service panel.
2. Route the
tubing through
the right hole
in the back to
the inlet water
solenoid valve
inlet in front.
3. Install a
compression
fitting on the
tubing and
connect to the
inlet of the
solenoid.
Note: Do NOT connect water to tubing in the back
of the unit. Water supply connects in the front.
Drains
There are two types of ice machine models, one
that drains by gravity and one that has an internal
drain pump.
Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing
secured to the back of the unit.
2. Route the plastic drain tube from the back of the
unit to the drain connection point.
IMPORTANT NOTE: Often an air gap is required by
local codes between the ice maker drain tube and
the drain receptacle.
September 2011
Page 10
SCCG30 & SCCP30
User Manual
Back View, Drain Pump Model
Water Inlet
Tube (field
supplied)
Drain Tube,
Route to
building drain
Screw Securing
Front Service
Panel
Loading ...