Loading ...
Loading ...
Loading ...
49-80507-6
15
INSTALLATION BELOW A SINGLE OVEN
INSTALLATION BELOW A DOUBLE OVEN
• When installed, the front face of the warming
drawer will be nearly flush with cabinetry doors
or drawer fronts.
• Drawer overlaps will conceal cut edges on all
sides of the opening.
The rough opening for the drawer must be:
³'HSWK 231/2” minimum from inside back to
front of cabinet frame.
³:LGWK 251/2” for 27” wide models
281/2” for 30” wide models.
³+HLJKW 91/4”
³ Allow 2” minimum between oven and drawer
cutouts for clearance of overlaps
NOTE: If you are installing in frameless cabinets,
it may be necessary to install 1/2” wide cleats to
accept drawer mounting screws. See drawer to find
exact locations of mounting screws.
When installed under a wall oven:
Warming drawers are suitable for installation below
only certain specified wall oven models. See the
label attached to the top of the warming drawer for
suitable models.
NOTE: Electrical receptacle can be installed as
shown for countertop installations. Do not install
receptacle above the top of the warming drawer
cutout.
PREPARING CABINET: BELOW WALL OVENS
INSTALLATION INSTRUCTIONS
Installation Instructions
23
1
/2”
Min.
2x2 or 2x4
anti-tip block
against rear
wall 9” from
floor to bottom
of block
1" Min. above toekick or
adjust to oven installation
height
A
NOTE: Additional clearance between cutouts
may be required. Check to be sure that oven
supports above the warming drawer location
do not obstruct the required interior 23
1
/2”
depth and 9
1
/4” height.
2" Min.
Allow 5/8”
overlap on
all sides
10
1
/2”
23
1
/4”
9"
9
1
/4”
B
Oven
cutout
Dimension A Dimension B
27" Drawer 25
1
/2” 26
3
/4”
30" Drawer 28
1
/2” 29
3
/4"
IN CANADA, THE WALL OVEN
IS ONLY APPROVED FOR
INSTALLATION WITH A BOTTOM
CUTOUT AT A MINIMUM OF
32.5” FROM THE FLOOR.
CAUTION
NOTE: Additional clearance between cutouts
may be required. Check to be sure that oven
supports above the warming drawer location
do not obstruct the required interior 23
1
/2”
depth and 9
1
/4” height.
2" Min
1" Min. above
toekick
2x2 or 2x4 anti-
tip block against
rear wall 9” from
floor to bottom
of block
23
1
/2”
Min.
Allow 5/8” overlap
on all sides
A
23
1
/4”
10
1
/2”
9"
9
1
/4”
Oven
cutout
B
IN CANADA, THIS DRAWER IS NOT APPROVED
FOR INSTALLATION UNDER A DOUBLE OVEN.
CAUTION
Loading ...
Loading ...
Loading ...