7. Allow oil to completely drain.
8. Fill crankcase with oil following the steps outlined in
Adding Engine Oil on page 18.
9. Dispose of used engine oil properly.
NOTICE
Never dispose of used engine oil by dumping the
oil into a sewer, on the ground, or into groundwater
or waterways. Always be environmentally
responsible. Follow the guidelines of the EPA or
other governmental agencies for proper disposal
of hazardous materials. Consult local authorities or
reclamation facility.
CHANGING ENGINE OIL
1. Stop the engine.
2. Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
3. Remove the engine service panel to gain access to
the oil ll/drain plug.
4. Place oil pan (or suitable container) under the oil ll/
drain plug (see Figure 13).
Figure 13: Place oil pan under oil ll/drain plug
5. With a damp rag, thoroughly clean around the oil
ll/drain plug.
6. Tilt the inverter so the oil drains down the through
into the container.
MAINTENANCE
AIR FILTER MAINTENANCE
WARNING
Never use gasoline or other ammable
solvents to clean the air lter. Use only
household detergent soap to clean the
air lter.
Cleaning the Air Filter
The air lter must be cleaned after every 50 hours of
use or 3 months (frequency should be increased if
inverter is operated in a dusty environment).
1. Turn o the inverter and let it cool for several
minutes if running.
2. Remove the engine service panel to gain access to
the air lter.
3. Unscrew the air cleaner cover and tip the cover
down (see Figure 15)
4. Remove the foam element from the air cleaner
housing.
oil pan
Figure 14: Carefully tip inverter so oil ows into oil pan
Figure 15: Unscrew air cleaner cover