15
LEVEL DRYER
Check the levelness of the dryer. Check levelness first side to side,
then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a
wrench to adjust the legs up or down and check again for levelness.
COMPLETE INSTALLATION
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see
which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check the dryer’s final location. Be sure the vent is not crushed
or kinked.
5. Check that the dryer is level. See “Level Dryer
.”
6. Remove the
blue film on the console and any tape remaining on
the dryer.
7. Wipe the dry
er drum interior thoroughly with a damp cloth to
remove any dust.
8. Read “Dryer Use.”
9. Fo
r power supply cord installation, plug into a grounded outlet.
For direct wire installation, turn on power.
Steam Models Only:
10. Be sure the water faucets are on.
11. Ch
eck for leaks around “Y” connector, faucet, and hoses.
12. If you live in a har
d water area, use of a water softener is
recommended to control the buildup of scale through the water
system in the dryer. Over time, the buildup of lime scale may clog
different parts of the water system, which will reduce product
performance. Excessive scale buildup may lead to the need for
certain part replacement or repair.
All Model
s:
13. Se
lect a Timed Dry heated cycle, and start the dryer. Do not select
the Air Only Temperature setting.
If the dryer
will not start, check the following:
Controls are set in a running or “On” position.
Start button has been pushed firmly.
Dryer is plugged into a grounded 3 prong outlet and/or
electrical supply is connected.
Household fuse is intact and tight, or circuit breaker has
not tripped.
Dryer door is closed.
This dryer automatically runs an installation diagnostic routine at the
start of its first cycle.
If you receive an L2 code, ther
e may be a problem with your
home power supply keeping the dryer’s heater from turning on.
See “Troubleshooting.”
14. When th
e dryer has been running for 5 minutes, open the dryer
door and feel for heat. If you feel heat, cancel cycle and close the
door.
If you do not feel heat, tu
rn off the dryer and check the
following:
There may be 2 household fuses or circuit breakers for the
dryer. Check that both fuses are intact and tight, or that both
circuit breakers have not tripped. If there is still no heat,
contact a qualified technician.
NOTE:
You may notice an odor when the dryer is first heated.
This odor is common when the heating element is first used.
The odor will go away.
TROUBLESHOOTING
First try the solutions suggested here and possibly avoid the cost of a service call...
Dryer Operation
Dryer will not run
Has a household fuse blown, or has a circuit breaker
tripped?
There may be 2 household fuses or cir
cuit breakers for the dryer.
Check that both fuses are intact and tight, or that both circuit
breakers have not tripped. Replace the fuse or reset the circuit
breaker. If the problem continues, call an electrician.
Is the correct power supply available?
Electric dryers require 240-volt power supply. Check with a
qual
ified electrician.
Was a regular fuse used?
Use a time-delay fuse.
No heat
Has a household fuse blown, or has a circuit breaker
tripped?
The drum may be turning, but you
may not have heat. Electric
dryers use 2 household fuses or circuit breakers. Replace the
fuse or reset the circuit breaker. If the problem continues, call an
electrician.
Dryer displaying code message
“PF” (power failure), check the following:
Was the drying cycle interrupted
by a power failure?
Press and hold START to restart the dryer.
“L2” Diagnostic Code (low or no line voltage condition):
The drum will turn, but there may be a problem with your home
power
supply keeping the dryer's heater from turning on. The
dryer will continue to run when this diagnostic code is present.
Press any key to clear the code from the display and return to
the estimated time remaining.