TO REMOVE:
Grasp the baffle filters from any one of their slats and pull them up, forward and out.
Grasp the drip tray and carefully lift it up out of the hood track. Remove baffles one at a
time.
To replace the drip trays:
1. Place and seat the drip tray into the hood track
2. Slide them left or right until all trays are side-by-side in place of the track.
To replace baffles:
1. Hold the baffle at the bottom by one of the slats
2. Place the other end of the baffle against the inside front of the hood
3. Slide it up and push the bottom end back until firmly sits in place
TO CLEAN HOOD SURFACE:
For general care, wipe the outside of the stainless steel with sudsy
water or household cleaners such as Fantastic® or Formula 409®,
rinse well and dry with clean soft cloth to avoid watermarks.
Wipe and dry brushed stainless steel in the same direction of the grain
Do not use abrasive products
DO NOT clean hood surface in a swirling motion, always clean in the
direction of the grain.
To remove fingerprints and give added shine use spray cleaners such
as Stainless Steel Magic® and Simmer®.
LIGHTS:
CAUTION! – Before replacing the lamps, switch power OFF at service panel and
lock service panel disconnecting means to prevent power from being switched ON
accidentally.
Note: -- Turn OFF the lights and fan. Allow the lights to cool before handling. If new
lights do not operate, be sure lights are inserted correctly before calling for service.
REPLACE LIGHT BULBS:
Remove the damaged bulb by unscrewing it (counter clockwise) and replace with a new
50 Watt Halogen narrow flood light bulb.
INFRARED LAMP:
Replace burned out infrared lamp with new lamp by turning bulb counterclockwise.
Use only the same make, model, and type of bulb (no substitutions allowed). Heat lamp
bulb is 250 Watt Infrared Bulb.
WARNING!To avoid any electrical shock the installation of the IR Lamp should
be done by a qualified electrician and before starting the installation of the hood.