Loading ...
Loading ...
Loading ...
Warning: in order to avoid damaging the sensor, never use silicone products near the hood!
Controls of Fig. 14
Button TC1 (Lights): Switches main light ON/OFFWhen the main light is on, BL1 changes colour and becomes active.When
the button is pressed for more than a second, it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1): Motor ON/OFF - Activates the motor at 1st speed.
Button TC3 (Motor-V2)Activates the motor at 2nd speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th speedMaximum speed is timed at a maximum of 5 minutes, after which
3rd speed is set automatically.When the motor is active, the LED of the last selected button (TC2-TC5) active to signal which
speed has been set.
Button TC6 (TIMER auto power off 5 min.)Activates the TIMER function at the speed that has already been selectedIf the
motor is NOT active, it switches on the motor at the 1st speed and activates the TIMER functionWhen the TIMER function
is active, BL6 becomes active.
30h filter ALARM: after 30 hours of operation, an alarm switches on to signal the need for anti-grease filter cleaning.The
filter alarm, when active, is displayed for 30 sec each time the motor is deactiva-ted:BL6 remains ON.During this period,
it is possible to reset the alarm by pressing the TC6 button for longer than a second.
120h filter ALARM: after 120 hours of operation, an alarm switches on to signal the need for active carbon filter (optional)
replacement.The filter alarm, when active, is displayed for 30 sec each time the motor is deactiva-ted:BL6 lighting
blinking.During this period, it is possible to reset the alarm by pressing the TC6 button for longer than a second.
Work Time Limit: if the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it
will automatically switch to OFF condition with all services switched off.
Buzzer: the Buzzer emits a "beep" each time that a command is set from the keyboard or remote control (optional).
Controls of Fig. 15
Button TC1 (Lights): Switches main light ON/OFFWhen the main light is on, BL1 changes colour and becomes active.When
the button is pressed for more than a second, it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1)Motor ON/OFF - Activates the motor at 1st speed.
Button TC3 (Motor-V2) Activates the motor at 2nd speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th speedMaximum speed is timed at a maximum of 5 minutes, after which
3rd speed is set automatically.When the motor is active, the LED of the last selected button (TC2-TC5) active to signal which
speed has been set.
Button TC6 (Auto ASC)Activates/deactivates the automatic ASC function.In this mode, motor speed increases or decreases
depending on the quantity of smoke and odours being produced under the hood. When the function is active, BL6 becomes
active.Each time that the motor changes speed, either automatically or forced by the user, BL6 lighting blinking for a few
seconds.
30h filter ALARM: After 30 hours of operation, an alarm switches on to signal the need for anti-grease filter cleaning.The
filter alarm, when active, is displayed for 30 sec each time the motor is deactivated:BL6 remains ON.During this period, it
is possible to reset the alarm by pressing the TC6 button for longer than a second.
120h filter ALARM: After 120 hours of operation, an alarm switches on to signal the need for active carbon filter (optional)
replacement.The filter alarm, when active, is displayed for 30 sec each time the motor is deactivated: BL6 lighting
blinking.During this period, it is possible to reset the alarm by pressing the TC6 button for longer than a second.
Buttons TC5 + TC6 (ASC sensitivity): ASC odour sensor sensitivity can be varied on 4 different levels as needed by pressing
buttons TC5 and TCS simultaneously for more than 1 second.The motor must be OFF and automatic function NOT active.When
sensitivity setting function is activated:all BL switch OFF (no display) then BL6 activates FIX.After 1 second, the BL2-BL5
LEDs will show the set sensitivity value, BL2 for lower sensitivity up to BL5 which indicates higher sensitivity. You can set
a different value using corresponding keys TC2, TC3, TC4 or TC5. To save the new sensitivity, press TC6 or wait until the
function deactivates automatically.
It can be varied on your keyboard (for cleaning) with a long press of the buttons TC1 and TC6 simultaneously. When the
cleaning mode is active, the keys TC1 and TC6 remain lit. To exit cleaning is necessary to activate the buttons again TC1
and TC6 pressed simultaneously (long), or wait for 5 minutes.
Work Time Limit: if the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user, it
will automatically switch to OFF condition with all services switched off.
Buzzer: the Buzzer emits a "beep" each time that a command is set from the keyboard or remote control (optional).
Warning: in order to avoid damaging the sensor, never use silicone products near the hood!
Cleaning the grease filters
WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk of fire, in according to use.
HOW TO REMOVE THE FILTERS: Remove the grease filters by moving fastener B and turning the filter outwards (Fig.5).
HOW TO CLEAN THE FILTERS: hand wash or in the dishwasher using a neutral detergent. If washing in the dishwasher,
possible discoloration of the filters does not in any way compromise their functioning.
Replacing the charcoal filters: for filtering hoods, the charcoal filters must be replaced. Replace it at least
every 6 months, in according to use. Removing the charcoal filters: before removing the charcoal filters, the grease
filters will have to be removed by moving catch B and turning the filter outwards (Fig. 5). Then remove the charcoal
filters by turning until they are released from the pins (Fig. 16).
Lighting:
Loading ...
Loading ...
Loading ...