Installation
48
Burner and nozzle characteristics tables
1 Natural Gas G20 - 20 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.00 1.70 2.60 2.90 4.00
Nozzle diameter (1/100 mm)
72 97 108 115 150
Pre-chamber (printed on nozzle)
(X) (Z) (Y) (Y) (H3)
Reduced flow rate (W)
400 500 800 800 1400
2 Natural Gas G20 - 25 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.10 1.80 2.60 2.80 4.00
Nozzle diameter (1/100 mm)
72 94 105 110 145
Pre-chamber (printed on nozzle)
(X) (Z) (Y) (H8) (H3)
Reduced flow rate (W)
400 500 800 800 1400
3 Natural Gas G25.3 - 25 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.00 1.70 2.50 3.00 4.00
Nozzle diameter (1/100 mm)
72 94 115 121 145
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (F2) (F3)
Reduced flow rate (W)
400 500 800 800 1400
4 Natural Gas G25.1 - 25 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.10 1.80 2.60 3.10 4.00
Nozzle diameter (1/100 mm)
77 100 124 134 148
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (F3) (F3)
Reduced flow rate (W)
400 500 800 800 1400
5 Natural Gas G25 - 20 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.10 1.70 2.60 3.00 4.00
Nozzle diameter (1/100 mm)
77 100 124 134 165
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (F3) (H3)
Reduced flow rate (W)
400 500 800 800 1400
6 Natural Gas G2.350 - 13 mbar AUX SR RR R UR2
Rated heating capacity (kW)
1.00 1.80 2.60 3.00 3.90
Nozzle diameter (1/100 mm)
94 120 152 165 190
Pre-chamber (printed on nozzle)
(Y) (Y) (F3) (F3) (F3)
Reduced flow rate (W)
400 500 800 800 1400
Loading ...