Jenn-Air UXT3030ADW

User Manual - Page 5

For UXT3030ADW.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
5
Installation Clearances
Venting System
Venting Methods
NOTES:
Flexible vent is not recommended. Flexible vent
createsbothback pressure and air turbulence
thatgreatlyreduce performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall.
Use3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular with a maximum
ventlength of 35 ft (10.7 m).
Top Venting Wall Venting
A
B
A
B
A. 3
1
/
4
" x 10" (8.3 x 25.4 cm)
rectangular vent through the
roof (purchased separately)
B. Roof cap with damper
(purchased separately)
A. 3
1
/
4
" x 10" (8.3 x 25.4 cm)
rectangular vent through
thewall or out the top
(purchased separately)
B. Wall cap with damper
(purchased separately)
Cold Weather Installations
An additional backdraft damper should be installed to
minimizebackward cold air ow and a thermal break should
beinstalled to minimize conduction of outside temperatures
aspart of the vent system. The damper should be on the cold
airside of the thermal break.
The break should be as close as possible to where the
ventsystem enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup
airsystemswhen using ventilation systems greater than
speciedCFM of air movement. The specied CFM varies
fromlocale to locale. Consult your HVAC professional
forspecic requirements in your area.
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic
orotherenclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use 3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular metal
vent,depending on your installation requirement.
Rigidmetalvent is recommended. Plastic or metal
foilventisnotrecommended.
The length of vent system and number of elbows should
bekept to a minimum to provide efcient performance.
For the most efcient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
ventbetween the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening
aroundthecap.
B
A
C
D
E
A. 24" (61 cm) minimum distance from electric cooking surface
24" (61 cm) minimum distance from gas cooking surface
30" (76.2 cm) suggested maximum above the cooking surface
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop
C. 30" (76.2 cm) minimum cabinet opening width
D. 12" (30.5 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
Loading ...
Loading ...
Loading ...