4
Pre-Installation - continued
Installation position
A Vertical height from bottom of Rangehood to Fixing Plate mounting screws
302mm.
B Set height from the hob surface to the underside face of the rangehood at 750mm for electric hob or gas
hob.
Please check that the length of your chimney assembly will reach your ceiling before securing the rangehood to
the wall.
Be advised that the chimney height is such that the optimum height for installation is 750mm above the hob.
Should you wish to have the unit lower, or you have a ceiling higher than the typical 2.4 meter (8 foot), then
please choose the desired chimney extension kit from page 8.
Minimum height from the hob surface to the underside face of the rangehood
600mm electric hob - chimney extension kit required, see page 8
650mm gas hob – chimney extension kit required, see page 8
Notes: If the instructions for the gas hob specify a greater distance, this has to be taken into account.
Any installation above 750mm will compromise the performance.
C Distance between mounting screw holes on Fixing Plate
115mm.
+
+
+