Scotsman Cu0515

User Manual - Page 3

For CU0515.

PDF File Manual, 16 pages, Read Online | Download pdf file

CU0515 photo
Loading ...
Loading ...
Spec i fi ca tions
The ice machine must be installed indoors in a
controlled environment.
Minimum Maximum
Air Temp 50
0
F. 95
0
F.
Water Temp 40
0
F. 100
0
F.
Water Pressure 20 PSI 80 PSI
Voltage 103.5 126.5
Operating the ice machine outside of the above
limitations, or outdoors, is potentially damaging to
the machine, and it is misuse of the machine. This
may void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of agencies like NSF and UL..
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
hat have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
UNPACKING AND INSPECTION
1. Call your authorized SCOTSMAN Distributor or
Dealer for proper installation.
2. Remove the front panel of the unit and inspect
for any concealed damage. Notify carrier of your
claim for the concealed damage.
3. Check that refrigerant lines do not rub against or
touch other lines or surfaces, and that the fan
blade moves freely.
4. Check that the compressor fits snugly onto all its
mounting pads.
5. Remove all internal support packing and
masking tape.
CU0515
August 2018
Page 2
Model Dimensions Basic Electrical Max Fuse Size
CU0515GA-1E 115/60/1 15
Loading ...
Loading ...
Loading ...