46 Part Number 000014141 Rev 07 2/20
Maintenance Section 4
Step 11 Use half of the sanitizer/water
solution to sanitize all food zone surfaces
of the ice machine and bin (or dispenser).
Use a spray bottle to liberally apply the
solution. When sanitizing, pay particular
attention to the following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top,
bottom and sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 12 Replace all removed components
back into their original configuration and
wait 20 minutes.
Notice
When re-installing the water level probe,
ensure the rubber gasket is sealed against
the base of the ice machine and that any
electrical connectors or wires remain free
from moisture.
Step 13 Press the Clean button and
select “Make ice when complete”. Water
will flow through the water dump valve
and down the drain. Wait approximately
1 minute until the water trough refills and
the display indicates Add Chemical. Add the
proper amount of ice machine sanitizer to
the water trough by pouring between the
water curtain and evaporator, then confirm
the chemical was added.
Model
Amount of
Sanitizer
IF0300/IT0300/IT0420/IT0450
IT0500/IF0500/IP0500/IP0520
IF0600/IT0620/IBF0620C
IT0750/IBF0820C/IF0900
IT0900/IT1200
3 oz
(90 ml)
IBT1020C
3.5 oz
(104 ml)
IT1500/IT1900
6 oz
(180 ml)
IF1400C/IF1800C/IF2100C
12 oz
(355 ml)
Step 14 Close and secure the front door.
The ice machine will automatically start ice
making after the sanitize cycle is complete
(approximately 24 minutes).