Rocketfish RF-HTS115 10Outlet Power Manager with Surge Protection and Noise Filtering Multi

QUICK SETUP GUIDE - Page 3

For RF-HTS115.

PDF File Manual, 4 pages, Read Online | Download pdf file

RF-HTS115 photo
Loading ...
Loading ...
ENGLISH 12-0773
10 Five master-controlled outlets – automatically shut down to
conserve energy when the device plugged into the master
outlet is turned o.
11 Four always-on outlets – provide continuous power
regardless of Master/Master-controlled outlets state.
3,450 joules surge protection – Protects your equipment
from damaging power surges and spikes.
70 dB EMI/RFI noise ltering – Ensures that your equipment
receives only clean power for maximum performance.
Audible alarm – Sounds when the surge protection feature has
reached full capacity and can no longer absorb surges and
spikes. The power manager should be replaced if this alarm
sounds.
Power cord labels – attach these labels to your power cords
(near the plug end) to help identify which cord is attached to
which device in the event that one should need to be
unplugged for any reason. The labels are pre-printed for
convenience, and the blank labels can be customized for
unique devices.
Operating instructions
1 Plug the power cord of the Rocketsh Power Manager into a
standard 120V AC outlet. If the LEDs do not light up, press the
main power switch/circuit breaker on the side of the unit.
2 Plug the power cord of your primary home theater device, such
as a TV, into the Master outlet of the Power Manager. When this
device is powered o or goes into a SLEEP or STANDBY mode,
power to the devices plugged into the Master-controlled outlets
will automatically be shut o, saving energy by preventing them
from drawing any standby current.
3 Plug the power cords of your secondary devices, such as a
Blu-ray/DVD player, A/V receiver, CD player, etc., into the
Master-controlled outlets of the Power Manager.
Note: Do not plug any device into a Master-controlled outlet that
you wish to use while the power of the primary device plugged
into the Master outlet is powered o, as these outlets only
provide power to the connected devices while the primary
device is powered on.
4 Plug the power cords of any devices that require constant power,
such as a DVR/PVR, or devices that you wish to use while the
primary device is powered o, into the Always-on outlets of the
Power Manager.
5 Connect the incoming coaxial cable source (i.e., the cable jack on
the wall or incoming satellite line) to the coaxial jack marked IN
on the Power Manager.
6 Connect a separate coaxial cable from the coaxial jack marked
OUT on the Power Manager to the coaxial input jack of the
cable/satellite set-top box.
7 Connect the incoming phone (RJ11) or Ethernet (RJ45) line to the
data line jack marked IN on the Power Manager.
8 Connect a separate phone or Ethernet cable from the data line
jack marked OUT on the Power Manager to the corresponding
input jack (phone or Ethernet) on the device (i.e., satellite set-top
box).
Note: the data line jacks are combo (RJ11/RJ45) jacks, meaning
they will accept either a RJ11 or RJ45 plug. They will not accept
both types of plugs simultaneously.
9 After all devices have been properly plugged into the Power
Manager and powered on, when you power the primary device
that is plugged into the Master outlet on and o, the secondary
devices that are plugged into the Master-controlled outlets will
automatically power on and o. Devices that are plugged into
the Always-on outlets will not be controlled by the primary
device, and must be powered on and o separately as desired.
Note: Should the Master-controlled outlets not power on and o
as described when the primary device plugged into the Master
outlet is powered on and o, it is possible that the primary
device draws too much current while in the OFF or STANDBY
mode. In the event this should occur with your equipment, try
plugging a dierent primary device into the Master outlet.
Specications
Load rating: 15 amps
Line voltage: 125V AC @ 60 Hz
Surge protection: 3 lines (L-N / L-G / N-G)
Maximum surge current: 180,000 amps
Maximum energy dissipation: 3,450 joules
Clamping voltage: L-N / L-G / N-G = 400 volts
EMI/RFI noise ltering: Up to 70 dB
Standby power consumption: 0.99 watts
• UL-1449 certied
Safety precautions
RISK OF ELECTRIC SHOCK–Use only in dry locations and only
indoors.
DO NOT plug into another relocatable power tap.
DO NOT daisy chain surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if correctly grounded outlets are not available.
DO NOT install this device if there is not at least 30 feet
(10 meters) or more of wire between the electrical outlet and
electrical service panel.
One-year limited product warranty
See included warranty sheet, visit www.rocketshproducts.com or
call 800-620-2790 for additional connected equipment and
product warranty information or for customer service.
© 2012 BBY Solutions, Inc., All Rights Reserved.
Distributed by Best Buy Purchasing, LLC
7601 Penn Avenue South, Richfield, MN USA 55423-3645
ROCKETFISH is a trademark of BBY Solutions, Inc. All other products and
brand names are trademarks of their respective owners.
Loading ...