3HUIRUPDQFH'DWD6KHHW
6PDUW:DWHU)LOWUDWLRQ6\VWHP*1695%/DQG*1695::8VLQJ)LOWHU)469)
7KLV6\VWHPKDVEHHQWHVWHGDFFRUGLQJWR16)$16,DQGIRUWKHUHGXFWLRQRIWKHVXEVWDQFHVOLVWHGEHORZ7KHFRQFHQWUDWLRQRIWKHLQGLFDWHGVXEVWDQFHVLQ
ZDWHUHQWHULQJWKHV\VWHPZDVUHGXFHGWRDFRQFHQWUDWLRQOHVVWKDQRUHTXDOWRWKHSHUPLVVLEOHOLPLWIRUZDWHUOHDYLQJWKHV\VWHP
DVVSHFLILHGLQ16)$16,DQG
$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
:$51,1*7RUHGXFHWKHULVNDVVRFLDWHGZLWKWKHLQJHVWLRQRIFRQWDPLQDQWVGRQRWXVHZLWKZDWHUWKDWLVPLFURELRORJLFDOO\XQVDIHRURI
XQNQRZQTXDOLW\ZLWKRXWDGHTXDWHGLVLQIHFWLRQEHIRUHRUDIWHUWKHV\VWHP6\VWHPVFHUWLILHGIRUF\VWUHGXFWLRQPD\EHXVHGRQGLVLQIHFWHGZDWHUWKDW
PD\FRQWDLQILOWHUDEOHF\VWV
6WDQGDUG1R$HVWKHWLF(IIHFWV
86(3$ ,QIOXHQW ,QIOXHQW
(IIOXHQW
5HGXFWLRQ
0LQ5HTXLUHG
3DUDPHDWHU 0&/ &KDOOHQJH&RQFHQWUDWLRQ $YHUDJH $YHUDJH 0D[LPXP $YHUDJH 0LQLPXP 5HGXFWLRQ
&KORULQHWDVWHDQGRGRU
³ PJ/ PJ/ PJ/ PJ/ !
3DUWLFXODWH ³ SDUWLFOHV 3DUWVP/ 3DUWVP/ 3DUWVP/ !
6WDQGDUG1R+HDOWK(IIHFWV
7XUELGLW\ 178 178 178 178 178 178
&\VWV UHG 0LQ/ &\VW/ &\VW/ &\VW/ ! !
$VEHVWRV UHG
DQG
ILEHUV/ 0)/ 0)/ 0)/ ! !
ILEHUV!PORQJ
/HDG PJ/ PJ/ PJ/ PJ/ PJ/ ! ! PJ/
S+
/HDG PJ/ PJ/ PJ/ PJ/ PJ/ ! ! PJ/
S+
0HUFXU\ PJ/ PJ/ PJ/ PJ/ PJ/ ! PJ/
S+
0HUFXU\ PJ/ PJ/ PJ/ PJ/ PJ/ PJ/
S+
/LQGDQH PJ/ PJ/ PJ/ PJ/ PJ/ ! PJ/
%HQ]HQH PJ/ PJ/ PJ/ PJ/ PJ/ ! ! PJ/
$WUD]LQH PJ/ PJ/ PJ/ PJ/ PJ/ ! ! PJ/
92&V PJ/ PJ/ PJ/ PJ/
7HVWHGXVLQJDIORZUDWHRIJSPOPLQSUHVVXUHRISVLJS+RIWHPSRI)&
0HDVXUHPHQWLQSDUWLFOHVP/3DUWLFOHVXVHGZHUH²PLFURQV
178³1HSKHORPHWULF7XUELGLW\8QLWV
%DVHGRQWKHXVHRI&U\SWRVSRULGLXPSDUYXPRRF\VWV
0D[LPXP
3HUPLVVLEOH
3URGXFW:DWHU
&RQFHQWUDWLRQ
2SHUDWLQJ6SHFLILFDWLRQV
&DSDFLW\FHUWLILHGIRUXSWRJDOORQVO
3UHVVXUHUHTXLUHPHQW²SVL²EDU
7HPSHUDWXUH²)²&
)ORZUDWHJSPOPLQ
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: February 9, 2009
Trademark/Model Designation
Replacement Element(s)
160104 -
GXSV65 F FQSVF
GQSV65 F FQSVF
GNSV70 FBL FQSVF
GNSV75 FWW FQSVF
GXSV65 R FQSVF
GNSV75 RWW FQSVF
GNSV70 RBL FQSVF
Manufacturer: General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Cysts
Turbidity
Asbestos
Lead
Mercury
Atrazine
Lindane
Benzene
VOCs
Alachlor
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb
Endrin
Ethylbenzene
EDB
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
Methoxychlor
Pentachlorophenol
Simazine
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)
Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane
Xylenes
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
160 galRated Service Capacity: 0.6 gpm
Rated Service Flow: