22 Part Number:040005890 Rev 05 12/19
Troubleshooting Section 5
Problem Possible Cause To Correct
Low ice capacity.
The condenser is dirty. Clean the condenser.
High air temperature around ice machine (air-
cooled models).
Air temperature must not exceed 110°F
(43°C).
Inadequate clearance around the ice
machine.
Provide adequate clearance.
Objects stacked around ice machine, blocking
airflow to condenser (air-cooled models)
Remove items blocking airflow.
Hot incoming water. Connect the ice machine to a cold water
supply.
Incorrect incoming water pressure. Water
pressure is too low or water filter is restricted.
Water pressure must be 20 – 80 psi (137.9 –
551.5 kPa). Refer to section 2 for plumbing
requirements. Replace water filter.
Safety Limit Feature
In addition to the standard safety controls, such as the high pressure cutout, your Manitowoc ice machine features built-in
safety limits, which will stop the ice machine if conditions arise which could cause a major component failure.
Before calling for service, re-start the ice machine using the following procedure:
1. Press the On/Off button and turn off the ice machine, then press the On/Off button again to start the ice machine.
A. If the safety limit feature has stopped the ice machine, it will restart after a short delay. Proceed to step 2.
B. If the ice machine does not restart, see “Ice machine does not operate” on the previous page.
2. Allow the ice machine to run to determine if the condition is recurring.
A. If the ice machine stops again, the condition has recurred. Call for service.
B. If the ice machine continues to run, the condition has corrected itself. Allow the ice machine to continue running.