45
Consumer SupportOperating Instructions
Safety Instructions
Installation Instructions Troubleshooting Tips
3-Wire Power Cord Installation Option
WARNING: The neutral or ground wire
of the power cord must be connected to the neutral
terminal located in the center of the connector block.
The power leads must be connected to the outside
(brass-colored) terminals.
Locate the ground strap in
the installation accessory pack
(packed with the oven shelves
on new ranges).
Insert the ground strap under the neutral
terminal on the connector block. Connect
the other end of the ground strap to the
grounding plate using the ground screw.
Insert the replacement power cord through
the strain relief and tighten. Allow enough
slack to easily attach the cord terminals to
the connector block. If tabs are present at
the end of the winged strain relief, they
can be removed for better fit.
NOTE: Do not install the power cord without a strain
relief. The strain relief bracket should be installed
before reinstalling the rear range wiring cover.
Insert screws through each power cord
terminal ring and into the connector block
until the screws engage the nuts. Be certain
that the center wire is connected to the
center screw of the connector block.
Tighten screws securely.
Connector block
Ground screw
Power cord
Neutral terminal
Ground strap