Touch Screen Features
Buttons
Touchscreen
Icons: Provide status indication and allow navigation by pressing the icon.

Setup Wizard: Screens will automatically advance after a selection is made or press the right arrow to advance one screen, press left arrow to go back one screen. All settings can be accessed and changed without the wizard by using menu screen navigation.
| Setup | Description |
| Press ON/ OFF Button | On/Off button is used to start/stop ice making. |
| Enter Model Number | Only visible if model number can not be automatically identified. The ice machine will not start without model identification |
| Select Language | Default is English. Scroll to select a different language |
| Start Wizard | Setup wizard will guide ice machine programming |
| Accessory Detection | Detects if Ice Level Sensor, LuminIce II or AuCS are connected. Checkmark = yes - X = no |
| USB Setup | Only used when setup features have been transferred to a USB drive. Skip screen by selecting right arrow. |
| Configure Date and Time Formats | Select Month/Day/Year or Day/Month/Year. Select 12 hour or 24 hour time format |
| Set Time | Use arrows to set local time |
| Set Date | Use arrows to set date for your location. |
| Units | Select standard or metric |
| Brightness | Configure screen brightness during normal operation. |
| Ice Program | Program ice machine run times or press right arrow to skip this setup |
| Cleaning Reminder | Set descale or sanitize reminder or press right arrow to skip. |
| IAuCS Only when detected | Set frequency of operation when this accessory is installed. |
| Air Filter Air-cooled models only | Set to ON for self-contained air cooled models. |
| Water Usage | Factory default or Use less water for reverse osmosis systems or Use more water to improve clarity for unfiltered water |
| Water Filter | Select Yes or No. |
| LuminIce II Only when detected | 12 month reminder is automatically set. |
| Ice Level Sensor Only when detected | Reminder to rotate the sensor from shipping to operational position |
| Wizard Complete | Press right arrow or home icon to return to home screen. |
Menu Screen Navigation: Select SETTINGS Icon from the Home Screen to access Main Menu screen.

The control board has the following nonadjustable timers:
Service Faults are stored and indicated by the control board after three cycles. The number of cycles required to stop the ice machine varies for each Service Fault.
Refer to Section 5 if you receive an alert for Service Fault E01 or E02.
Allows the ice machine to operate up to 72 hours if the ice thickness probe and/or water level probe sensors fail.
NOTE: The control board needs a five cycle history to operate safe mode. If five cycles have never been successfully completed the ice machine will shut-off.
When the damper/curtain does not open within 3.5 minutes in the harvest cycle the following occurs:
When the damper/curtain does not open during the 7 minute harvest cycle the following water thaw cycle occurs:
Adjust ice thickness to meet chart specifications.

Important: Routine adjustments and maintenance procedures are not covered by the warranty.
After a harvest cycle, inspect the ice cubes in the ice storage bin. The ice thickness probe is factory-set to maintain the ice bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is in place when performing this check. It prevents water from splashing out of the water trough
NOTE: Turning the adjustment one-third of a turn will change the ice thickness about 1/16" (1.5 mm).

When using water with low total dissolved solid content (low TDS) the water level probe sensitivity can be increased by moving the jumper over one pin. The Electronic Control Board diagram shows the default position of the jumper covering the left and center pins. Moving the jumper to the center and right pins and enabling R.O. menu “Use less water with reverse osmosis” (Settings/Energy/ Water Usage/Use Less Water With Reverse Osmosis) will increase the sensitivity of the water level probe.

General
Ice Machine Inspection
Exterior Cleaning
Remedial Cleaning Procedure
Detailed Descaling/Sanitizing Procedure: This procedure must be performed a minimum of once every six months.
Caution: Use only Manitowoc approved Ice Machine Cleaner/De-scaler and Sanitizer for this application (Manitowoc Cleaner/De-scaler part number 9405463 and Manitowoc Sanitizer part number 9405653). It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. Read and understand all labels printed on bottles before use.
Ice machine cleaner/descaler is used to remove lime scale and mineral deposits. Ice machine sanitizer disinfects and removes algae and slime.
NOTE: Although not required and dependent on your installation, removing the ice machine top cover may allow easier access.
Step 1 Open the front door to access the evaporator compartment. Ice must not be on the evaporator during the descaling/ sanitize cycle. Follow one of the methods below:
Notice: Never use anything to force ice from the evaporator. Damage may result.
Step 2 Remove all ice from the bin/ dispenser.
Step 3 Press the Clean button and select “Turn off when complete”. Water will flow through the water dump valve and down the drain. Wait approximately 1 minute until the water trough refills and the display indicates Add Chemical. Add the proper amount of ice machine cleaner/descaler to the water trough by pouring between the water curtain and evaporator, then confirm the chemical was added.
Caution Do not mix Cleaner/Descaler and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling.
Warning Wear rubber gloves and safety goggles (and/or face shield) when handling Ice Machine Cleaner/Descaler or Sanitizer.
| Model | Amount of Cleaner/ Descaler |
| IF0300/IT0300/IT0420/ IP0520/IT0620 | 3 oz (90 ml) |
| IT0450/IT0500/IF0500 IP0500/IF0600/IT0750 IF0900/IT0900/IT1200 | 5 oz (150 ml) |
| IBF0620C/IBF0820C IBT1020C | 5 oz (150 ml) |
| IF1400C/IT1500/IT1700 IF1800C/IT1900/IF2100C | 9 oz (265 ml) |
Step 4 Wait until the cycle is complete (approximately 24 minutes). Then disconnect power to the ice machine (and dispenser when used).
Warning Disconnect the electric power to the ice machine at the electric service switch box.
Step 5 Remove parts for descaling.
Notice Refer to parts removal page 47. Continue with Step 6 when the parts have been removed.
Step 6 Mix a solution of cleaner/descaler and lukewarm water. Depending upon the amount of mineral buildup, a larger quantity of solution may be required. Use the ratio in the table below to mix enough solution to thoroughly descale all parts.
| Solution Type | Water | Mixed With |
| Cleaner/ Descaler | 1 gal (4 L) | 16 oz (475 ml) cleaner/descaler |
Step 7 Use half of the cleaner/descaler & water mixture to descale all components. Use caution not to expose electrical connectors to liquid and soak parts for 5 minutes (15 - 20 minutes for heavily scaled parts). The solution will foam when it contacts lime scale and mineral deposits; once the foaming stops, use a soft-bristle nylon brush, sponge or cloth (NOT a wire brush) to carefully descale the parts. When descaling is complete rinse all removed components with clean water
Step 8 While components are soaking, use half of the solution to descale all food zone surfaces of the ice machine and bin (or dispenser). Use a nylon brush or cloth to thoroughly descale the following ice machine areas:
SANITIZING PROCEDURE
Step 9 Mix a solution of sanitizer and lukewarm water.
| Solution Type | Water | Mixed With |
| Sanitizer | 3 gal (12 L) | 2 oz (60 ml) sanitizer |
Step 10 Use half of the sanitizer/ water solution to sanitize all removed components. Fill a spray bottle and use caution not to expose electrical connectors to liquid and liberally apply the solution to all surfaces of the removed parts or soak the removed parts in the sanitizer/water solution. Do not rinse parts after sanitizing
Step 11 Use half of the sanitizer/water solution to sanitize all food zone surfaces of the ice machine and bin (or dispenser). Use a spray bottle to liberally apply the solution. When sanitizing, pay particular attention to the following areas:
Do not rinse the sanitized areas.
Step 12 Replace all removed components back into their original configuration and wait 20 minutes.
Notice When re-installing the water level probe, ensure the rubber gasket is sealed against the base of the ice machine and that any electrical connectors or wires remain free from moisture.
Step 13 Press the Clean button and select “Make ice when complete”. Water will flow through the water dump valve and down the drain. Wait approximately 1 minute until the water trough refills and the display indicates Add Chemical. Add the proper amount of ice machine sanitizer to the water trough by pouring between the water curtain and evaporator, then confirm the chemical was added.
| Model | Amount of Sanitizer |
| IF0300/IT0300/IT0420/IT0450 IT0500/IF0500/IP0500/IP0520 IF0600/IT0620/IBF0620C IT0750/IBF0820C/IF0900 IT0900/IT1200 | 3 oz (90 ml) |
| IBT1020C | 3.5 oz (104 ml) |
| IT1500/IT1900 | 6 oz (180 ml) |
| IF1400C/IF1800C/IF2100C | 12 oz (355 ml) |
Step 14 Close and secure the front door. The ice machine will automatically start ice making after the sanitize cycle is complete (approximately 24 minutes).
Single evaporator is shown; Each evaporator will have a distribution tube and water curtain/damper.
A. Remove the water curtain(s)
B. Remove the ice thickness probe
Notice Electrical connector must never be exposed to any liquids.
C. Remove the water trough
D. Remove the water level probe
Notice Electrical connector must never be exposed to any liquids.
E. Remove the water distribution tube(s)
NOTE: Thumbscrews for the distribution tube are retained to prevent loss. Loosen thumbscrews, but do not pull thumbscrews out of distribution tube.

Step 1 Ice must not be on the evaporator during the clean/sanitize cycle. Follow one of the methods below:
Notice Never use anything to force ice from the evaporator. Damage may result.
Step 2 Open the front door to access the evaporator.
Step 3 Press the Clean button and select “Make ice when complete”. Water will flow through the water dump valve and down the drain. Wait approximately 1 minute until the water trough refills and the display indicates Add Chemical. Add the proper amount of ice machine descaler to the water trough by pouring between the water curtain and evaporator, then confirm the chemical was added.
| Model | Amount of Cleaner/Descaler |
| IF0300/IT0420 IP0520/IT0620 | 3 oz (90 ml) |
| IT0450/IT0500/IF0500 IP0500/IF0600 IT0750/IF0900/IT0900 IT1200 | 5 oz (150 ml) |
| IBF0620C/IBF0820C IBT1020C | 5 oz (150 ml) |
| IF1400C/IT1500 IF1800C IT1900/IF2100C | 9 oz (265 ml) |
Step 4 Close and secure the front door. The ice machine will automatically start ice-making after the clean cycle is complete (approximately 24 minutes).
Warning Disconnect electric power to the ice machine at the electric service switch before cleaning the air filter or the condenser. The condenser fins are sharp; Use care when removing or installing the air filter.
All Models
1. Descale and sanitize the ice machine.
2. Turn off the water supply, disconnect and drain the incoming ice-making water line at the rear of the ice machine and drain the water trough.
3. Energize the ice machine, wait one minute for the water inlet valve to open and blow compressed air in both the incoming water and the drain openings in the rear of the ice machine to remove all water.
WATER-COOLED MODELS ONLY
All Models
4. Press the power switch and disconnect electrical power at the main disconnect/circuit breaker.
5. Fill spray bottle with sanitizer and spray all interior food zone surfaces. Do not rinse and allow to air dry.
6. Replace all panels.
If a problem arises during operation of your ice machine, follow the checklist below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty
| Problem | Possible Cause | To Correct |
| Ice machine does not operate. |
No electrical power to the ice machine and/or condensing unit High pressure cutout tripping Energy Saver or other field entered programming is stopping ice machine Water curtain off or stuck open Ice machine is not turned on.. IB Models Only - Dispenser ice level thermostat is open. |
Replace the fuse/reset the breaker/turn on the main switch. Clean condenser coil. Reset to factory defaults. Water curtain must be installed and swinging freely Press power button, display must indicate “Making Ice” Adjust thermostat to maintain correct dispenser level |
| Ice machine stops, and can be restarted by pressing the power switch | Service Fault feature stopping the ice machine | Refer to “Service Faults” |
| Ice machine does not release ice or is slow to harvest. |
Ice machine is dirty Ice machine is not level. Low air temperature around ice machine head section. Fan cycle control does not deenergize condenser fan motor. Water regulating valve incorrectly adjusted or will not close |
Descale and sanitize the ice machine. Level the ice machine Air temperature must be at least 35° (2°C). Call for service. Check for water at condenser drain outlet in harvest cycle. Contact a qualified service company to adjust/replace valve if water is present
|
| Ice machine does not cycle into harvest mode. |
The six-minute freeze time lock-in has not expired yet Ice thickness probe is dirty Ice thickness probe is disconnected. Ice thickness probe is out of adjustment Uneven ice fill (thin at the top of evaporator). |
Wait for the freeze lock-in to expire. Descale and sanitize the ice machine Connect the probe to the control board. Adjust the ice thickness probe. Verify sufficient water level in sump trough. Contact a qualified service company to check refrigeration system. |
| Ice quality is poor (soft or not clear). |
Poor incoming water quality Water filtration is poor Ice machine is dirty. Water dump valve is not working Water softener is working improperly (if applicable). |
Contact a qualified service company to test the quality of the incoming water and make appropriate filter recommendations Replace the filter Descale and sanitize the ice machine. Disassemble and clean the water dump valve. Repair the water softener |
| Ice machine produces shallow or incomplete cubes, or the ice fill pattern on the evaporator is incomplete. |
Ice thickness probe is out of adjustment. Water trough level is too low Water inlet valve filter screen is dirty Water filtration is poor Hot incoming water. Water inlet valve is not working. Incorrect incoming water pressure. Ice machine is not level. |
Adjust the ice thickness probe Check the water level probe position. Remove the water inlet valve and clean the filter screen. Replace the filter Connect the ice machine to a cold water supply. Replace the water inlet valve. Water pressure must be 20 psi - 80 psi (140 kPa - 550 kPa) Level the ice machine |
| Low ice capacity. |
Water inlet valve filter screen is dirty. Incoming water supply is shut off. Water inlet valve stuck open or leaking. The condenser is dirty. High air temperature entering condenser The harvest assist air compressor is not functioning |
Remove the water inlet valve and clean the filter screen. Open the water service valve. Press the power button and turn off the ice machine, if water continues to enter water trough, replace the water inlet valve. Clean the condenser. Refer to minimum/maximum air temperature chart for your model Call for service. |
In addition to the standard safety controls, such as the high pressure cutout, your Manitowoc ice machine features builtin service faults which will stop the ice machine if conditions arise which could cause a major component failure.
Before calling for service, re-start the ice machine using the following procedure: