46. Status Check (Command: s v)
Checks the current signal of the product.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data 02: Check whether there is a signal
03: The monitor is currently in PM Mode
05: Checks whether luminance sensors 1 and 2
are functioning properly.
06: Luminance sensors currently being used:
07: Checks whether the Top, Bottom and Main
temperature sensors are functioning normally.
09: Fan Speed
Acknowledgment
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
Data 02 (when a signal is found)
Data 1 00: No signal
01: Signal present
Data 03 (when the monitor is currently in PM mode)
Data1 00: Screen is on
01: Screen is off
02: Screen Off Always is activated
03: Sustain Aspect Ratio is activated
04: Screen Off & Backlight On is activated
Data 05 (when checking whether the luminance
sensors are functioning properly)
Data1 00: Everything is normal
01: BLU sensor 1 normal, BLU sensor 2 down
02: BLU sensor 1 down, BLU sensor 2 normal
03: All sensors down
Data 06 (when checking which luminance sensor is in
use)
Data1 00: Luminance sensor 1 is in use.
01: Luminance sensor 2 is in use.
Data 07 (when checking whether the Top, Bottom
and Main temperature sensors are working
properly)
Data1 00: All temperature sensors are faulty
01: Top normal, Bottom faulty, Main faulty
02: Top faulty, Bottom normal, Main faulty
03: Top normal, Bottom normal, Main faulty
04: Top faulty, Bottom faulty, Main normal
05: Top normal, Bottom faulty, Main normal
06: Top faulty, Bottom normal, Main normal
07: All temperature sensors are normal
Data 09 (when checking the fan speed)
Acknowledgment
[v][ ][Set ID][ ][OK/NG][Data][Data1][Data2][x]
Data1 00: Fan speed upper 1 Byte
Data2 00: Fan speed bottom 1 Byte
Fan Speed: Fan speed: 0 to 2008 in hexadecimal
and 0 to 8200 in decimal
* This feature may not be available for all models.
47. Daylight Saving Time (Command: s d)
Sets Daylight Savings Time.
Transmission
[s][d][ ][Set ID][ ][Data1][ ][Data2][ ]
[Data3][ ][Data4][ ][Data5][ ][Cr]
Data1 00: Off (Data2-5: FF)
01: Start Time
02: End Time
Data2 01~0C: January - December
Data3 01-06: Week 1 - 6
* The maximum value of [Data3] may vary depending on the
date.
Data4 00-06: (Sunday - Saturday)
Data5 00-17: 00 - 23 hours
* If you wish to read the start/end times, enter FF for
parameters [Data2] through [Data5].
(Example 1: sd 01 01 ff ff ff ff - Checks the start time.
Example 2: sd 01 02 ff ff ff ff - Checks the end time.)
* This feature only works when Clock 1 (year/month/day) and
Clock 2 (hour/minute/second) have been set.
Acknowledgment
[d][ ][Set ID][ ][OK/NG][Data1][Data2]
[Data3][Data4][Data5][x]
* This feature may not be available for all models.