Console shuts off (enters
sleep mode) while in use
Check data cable integrity All wires in the cable should be intact. If any are cut or
crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented prop-
erly. Small latch on connector should line up and snap
into place.
Reset machine Unplug unit from electrical outlet for 3 minutes. Recon-
nect to outlet.
If bike has batteries, check
Battery Level icon on console
or check batteries.
If the battery level shows low or no power, replace the
batteries.
Check magnet position (re-
quires shroud removal)
Magnet should be in place on pulley.
Check RPM Sensor (requires
shroud removal)
RPM sensor should be aligned with magnet and con-
nected to data cable. Realign sensor if necessary.
Replace if there is any damage to the sensor or the con-
necting wire.
Unit rocks/does not sit
level
Check leveler adjustment Leveling feet may be turned in or out to level bike.
Check surface under unit Adjustmentmaynotbeabletocompensateforextreme-
ly uneven surfaces. Move bike to level area.
Pedals loose/unit difficult
to pedal
Check pedal to crank
connection
Pedal should be tightened securely to crank. Be sure
connection is not cross-threaded.
Clicking sound when
pedaling
Check pedal to crank
connection
Remove pedals and reattach fully.
Seat post movement Check locking pin Be sure adjustment pin is locked into one of the seat
post adjustment holes.
Check adjustment knob Be sure knob is securely tightened.