Faber LEVG24SS300 Levante G

User Manual - Page 15

For LEVG24SS300.

PDF File Manual, 100 pages, Download pdf file

Loading ...
Loading ...
Loading ...
15
b1
a
b2
Remove the indicated blower cover
(do not discard the screw).
Reinstall the existing Grease Filters
after installing the Activated Charcoal
Filter before operating hood.
Reinstall the modied blower cover
with the same screw.
Cut the
cover
where
indicated in
picture b1.
Discard /
Recycle
upper
pieces of
blower
cover.
d
b3
NON DUCTED RECIRCULATION OPTION
Go to page 20
Required Activated Charcoal
Filter Accessory - (FILTER5)
purchased separately.
c
Non Ducted installations only:
1. Remove the two screws located on the motor
housing in the location indicated.
2. Place the charcoal lter with the tabs against
the blower housing in the location indicated on
gure
c
. The front side of the FILTER5 will
have the keyhole mounting on the top surface
of the lter. A layer of charcoal will be visible
through the grills.
3. Use the two screws removed earlier to attach
the FILTER5 in place.
NOTE: For Non ducted installations the Canadian
Grid should NOT be used.