ASSEMBLY
Lie vacuum flat and attach cleaner head by sliding it on until it clicks.
Stand vacuum up straight, attach wand to hose and push into place until it clicks.
Push wand down into hose and attach tools to the side of the vacuum.
USING YOUR DYSON VACUUM
Press foot pedal and recline handle to use. The stabilizer stand will automatically
lift up. To switch ‘ON, depress power button in front of handle. After cleaning,
push vacuum into an upright position and stabilizer wheels will automatically
drop. Use the cyclone carry handle to carry the vacuum.
CAUTION:
Do not use or store this machine below 32°F(0°C). Ensure that the machine is at
room temperature before operating.
Do not allow the vacuum to be used by anyone who may not be able to
operate it safely.
The use of an extension cord is not recommended.
Always switch off and unplug the vacuum before performing maintenance on
your vacuum.
When returning to the upright position, ensure that the stabilizer wheels are fully
engaged before releasing the vacuum.
Ensure the cyclone is secured to the vacuum. Do not press the cyclone release
button or shake the vacuum while carrying or it could fall and cause injury.
Store the vacuum indoors. Put the vacuum away after use with the cord coiled
safely, to prevent tripping hazards.
Do not use outdoors or on wet surfaces or to vacuum water or other liquids –
electric shock could occur.
Check to ensure your electricity supply corresponds to that shown on the rating
plate, which can be found behind the clear bin. The vacuum must only be used
as rated.
Do not lubricate any parts, or carry out any maintenance or repair work
other than that shown in this Dyson Operating Manual, or advised by the
Dyson Helpline.
PLEASE NOTE:
This vacuum is intended for domestic use only. Fine dust such as plaster dust or
flour should only be vacuumed in very small amounts.
Do not use the vacuum to pick up sharp hard objects, small toys, pins, paper
clips, etc. They may damage the vacuum.
Consult your flooring manufacturer’s recommended instructions before
vacuuming and caring for your flooring, rugs, and carpet. The brush bar on the
machine can damage certain carpet types and floors.
If unsure turn brush bar off in order to enable proper operation. Some carpets
will fuzz if a rotating brush bar is used when vacuuming. If this happens, we
recommend vacuuming in bare floors mode and consulting with your flooring
manufacturer.
When vacuuming, certain carpets may generate small static charges in the
clear bin or wand. These are entirely harmless and are not associated with the
electricity supply. To minimize any effect from this, do not put your hand or
insert any object into the clear bin unless you have first emptied it and rinsed it
out with cold water (see ‘clear bin cleaning section).
CARPETS/HARD FLOORS
The brush bar will always default to ‘ON’ (spinning) each time you switch on
the vacuum and recline it for cleaning. The brush bar will automatically stop
if it becomes obstructed. If the brush bar stops during use, please refer to the
‘Clearing brush bar obstructions’ section.
To switch the brush bar off (e.g. for hard floors), recline the vacuum and
turn it ‘ON, then press the brush bar ‘ON/OFF’ button – the brush bar
will stop spinning.
HIGH-REACH CLEANING
CAUTION:
Switch ‘OFF’ vacuum before changing tools.
Powerful suction can cause the hose to ‘pull back’ - please take care.
Take extra care when vacuuming on stairs; do not work with the vacuum above
you on the stairs. Do not put the vacuum on chairs, tables etc.
Ensure vacuum is in upright position before using tools.
PLEASE NOTE:
To release the wand, open the wand cap and pull the red tube until the wand
releases from the vacuum. Tools can be attached to either the hose or wand.
The brush bar will not rotate when the vacuum is in an upright position.
Ensure wand cap is closed when not in use.
CLEAR BIN EMPTYING
CAUTION:
PLEASE NOTE:
Switch ‘OFF’ vacuum and unplug the vacuum before emptying the clear bin
Empty as soon as the dirt reaches the level of the MAX mark – do not overfill.
To remove the clear bin from the vacuum press the button at rear of cyclone
carrying handle. To release the dirt, press the red clear bin release button.
Do not use the vacuum without the clear bin in place.
To minimize dust/allergen contact when emptying, encase bin tightly in a plastic
bag and empty. Remove bin carefully and seal bag tightly, dispose as normal.
CLEAR BIN CLEANING
CAUTION:
Do not immerse the whole cyclone in water or pour water into the cyclones.
Ensure the clear bin is completely dry before replacing.
PLEASE NOTE:
Do not use detergents, polishes or air fresheners to clean the clear bin.
Do not put the bin in a dishwasher.
When vacuuming, certain carpets may generate small static charges in the clear
bin. These are entirely harmless and are not associated with the mains supply.
To minimize any effect from this, do not put your hand or insert any object into
the clear bin unless you have first emptied it and rinsed it out with cold water.
Clean the shroud with a cloth or dry brush to remove lint and dust.
WASHING YOUR FILTERS
DO THIS EVERY 3 MONTHS
CAUTION:
Switch ‘OFF’ and unplug the vacuum before removing the filters.
Ensure filters are completely dry before refitting to the vacuum.
PLEASE NOTE:
This vacuum has two filters, located as shown. It is important to check your
filters regularly and wash at least every 3 months according to instructions, to
maintain performance.
The filter in the ball should be rinsed and tapped out until the water runs clean,
then tapped out again to ensure all excess water is removed. Please leave to dry
completely for 24 hours.
It is normal for this filter in the ball to turn grey in color. The filters may require
more frequent washing if vacuuming fine dust.
Do not use detergents to clean the filters.
Do not put the filters in a dishwasher, washing machine, tumble dryer, oven,
microwave or near an open flame.
LOOKING FOR BLOCKAGES
CAUTION:
Switch ‘OFF’ and unplug the vacuum before checking for blockages. Failure to
do so could result in personal injury.
Please ensure the vacuum is upright and switched off before removing hose or
airway inspection parts.
Beware of sharp objects when clearing blockages.
Refit all parts of the vacuum securely before using.
PLEASE NOTE:
Clearing blockages is not covered by your vacuum’s limited warranty.
This vacuum is fitted with a thermal cut-out. If any part of your vacuum becomes
blocked, it may overheat and then automatically shut off. Switch ‘OFF’ and
unplug the vacuum and leave to cool down for at least 60 minutes before
attempting to check filters or for blockages. Clear blockage before restarting.
CLEARING BRUSH BAR OBSTRUCTIONS
CAUTION:
Switch off and unplug the vacuum before clearing brush bar obstructions.
Failure to do so could result in personal injury.
If your brush bar is obstructed, it may shut off. If this happens you will need to
remove the brush bar as shown and clear any obstructing debris. Refit all parts
securely before use.
Beware of sharp objects when clearing obstructions.
Refit all parts of the vacuum securely before using.
PLEASE NOTE:
Cleaning the brush bar obstructions is not covered by your vacuum’s limited
warranty.