KitchenAid KXD4636YSS 36-in 600 CFM Downdraft Range Hood Stainless Steel

User Manual - Page 15

For KXD4636YSS.

PDF File Manual, 56 pages, Read Online | Download pdf file

KXD4636YSS photo
Loading ...
Loading ...
Loading ...
15
INSTALLATION INSTRUCTIONS
EXTERIOR-MOUNTED VENT MOTOR
CAUTION: To reduce the risk of fire and electrical shock, install
the downdraft only with remote blower systems that are sold by
Whirlpool Corporation. Model numbers UXI0600DYS (600 cfm)
and UXI01200DYS (1200 cfm).
NOTE: Exterior mounted vent motor installations require an
approved in-line blower motor system. Model numbers
UXI0600DYS (600 cfm) and UXI1200DYS (1200 cfm) are available
from your dealer or authorized parts supplier. See “Blower motor
system” in the “Accessories” section.
Venting Methods
Determine which venting method is best for your application.
Vent system can terminate through the wall or roof. A wall cap or
roof cap is required.
NOTES:
Venting through a concrete slab is not recommended.
The in-line blower motor system must be placed in an
enclosed area and can be located in a utility room, basement,
crawl space or attic. Observe all governing codes and
ordinances.
10" (25.4 cm) round vent duct is required for connections to
the retractable downdraft vent system outlet cover and the
in-line blower motor inlet and outlet covers. 10" (25.4 cm)
round vent duct is recommended for the retractable
downdraft vent system with in-line blower motor system.
Transitioning to different size ducting will reduce the
efficiency of the retractable downdraft vent system.
Built-In Cabinet Locations
Calculating Vent System Length
It is recommended that you use round vent instead of rectangular
vent, especially if elbows are required. If rectangular vent is
required, it should be transitioned to 10" (25.4 cm) round vent as
soon as possible.
Maximum Length of Vent System
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
The maximum equivalent vent lengths of 10" (25.4 cm) round
vents - 60 ft (18.3 m).
NOTE: The exterior-mounted vent motor requires a separate
wiring cable that should be installed at the same time the vent
work is installed.
Island location - front vent Island location - rear vent
To attic
installed in-line
blower motor system
To basement, crawlspace
or utility room installed
in-line blower motor system
To basement, crawlspace
or utility room installed
in-line blower motor system
To attic
installed in-line
blower motor system
Vent Length
10" (25.4 cm) round 60 ft (18.3 m)
Vent Piece 10" (25.4 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
2 - 90° elbows = 10.0 ft (3 m)
10 ft (3 m) straight = 10.0 ft (3 m)
Length of 10" (25.4 cm)
system
= 20 ft (6 m)
To attic
installed in-line
blower motor system
To basement, crawlspace
or utility room installed
in-line blower motor system
Loading ...
Loading ...
Loading ...