4
3. BUILD FRAMEWORK
HD1152A
FRAMING BEHIND DRYWALL
WALL STUDS
35” = BOTTOM OF HOOD 24” ABOVE COOKTOP
41” = BOTTOM OF HOOD 30” ABOVE COOKTOP
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
When building framework, always follow all applicable construction codes and standards.
Construct wood wall framing that is even with the surface of wall studs.
Wood wall framing must be at least 1/2” thick and 3” high. Fasten wood wall
framing to wall studs for a solid installation.
Make sure that the height of the framing will allow the retaining screws to be
secured to the framing within the dimensions shown.
After wall surface is finished, using a level, draw a vertical line up to the
ceiling starting from the center of the planned hood location. Measure and mark
the retaining screw locations using the measurements given in illustration at
right. Insert 2 M4 x 38 Phillips round head mounting screws in wall framing; do
not completely tighten the screws at this time.
4. INSTALL UPPER FLUE MOUNTING BRACKET (DUCTED INSTALLATION ONLY)
Center the upper flue mounting bracket with the center line previously
drawn in step 3 and place it flush with the ceiling. Use the upper flue
mounting bracket as a template to mark the position of its screws.
Secure the upper flue bracket to the wall using 2 M4 x 38 Phillips round
head mounting screws. Make sure that the bracket is tight against the
wall.
5. INSTALL PLENUM (NON-DUCTED INSTALLATION ONLY)
Center the plenum (included in the non-duct kit) with the center line previously
drawn in step 3 and place it flush with the ceiling. Use the plenum mounting
slots as a template to mark the position of its screws.
Secure the plenum to the wall using 2 M4 x 38 Phillips round head mounting
screws. Make sure that the plenum is tight against the wall.
C
L
HD1154
CENTER OF INSTALLATION
UPPER FLUE MOUNTING
BRACKET SLOTS
MOUNTING BRACKET
FLUSH WITH CEILING
CEILING
L
C
HD1158
CEILING
PLENUM
FLUSH WITH
CEILING
CENTER OF
INSTALLATION
PLENUM
MOUNTING
SLOTS
Loading ...