Connect the Wires
STEP 1
Connect the first line/load (black)
wire on the switch to the line or
load (black label) wire from the
wall.
STEP 2
Connect the second line/load
(black) wire on the switch to the
line or load (black label) wire from
the wall.
STEP 3
Connect the ground (green)
wire on the switch with the ground
(green label) wire from the wall.
STEP 4
Cap the 3-way/multi-way traveler
wire (if applicable).
For 3-way switch setup, visit
gelighting.com/cync
Attention: Incorrectly
connecting the ground wire
from the wall to the ground
wire on the switch will
damage the product.
STEP 5
Cap the neutral wire from the wall
(if applicable). Neutral wire is not
required to operate this switch.
NOTE Both black wires on the switch are interchangeable and can be
connected to either the load or line wire from the wall.
3/4 inch
USING WIRE NUTS
1. Insert wires into wire nut.
2. Turn wire nut clockwise.
3. Pull gently on wires to test connection.