150 Part Number: 000015430 Rev 02 5/20
3. Disconnect the water level probe wiring harness from
the control board and ohm harness and water level
probe. Normal readings will show no resistance
Black
Short Probe
Red
Twisted
Wire
Ohm Water Level Probe and Wiring Harness
WATER LEVEL PROBE CIRCUIT CHECK AT CONTROL
BOARD
Wait until prechill cycle starts, then jumper water level
probe connections (Red/Black) on the control board.
A. Sensing displays and the water stops. Repair wire
or replace water level probe.
B. Not Sensing displays and the water continues to
flow. Replace control board.