6
6. Using diagonal wire cutting pliers, gently snip out the
rectangular damper vent covers at the perforations.
7. Hold the blower motor wire, put the wire through the blower
motor bridge.
8. Lower blower motor back into the microwave oven. Exhaust
ports face the back of the microwave oven.
9. Reconnect the blower motor wire into the connector.
10. Reattach the 2 blower screws into the recessed holes in the
back of the microwave.
11. Check to make sure the 2 screws are secured properly in the
blower motor screw holes, so that the motor cannot move.
12. Return the damper plate to its original horizontal position.
B
A
A. Diagonal wire cutting pliers
B. Rectangular damper vent cover
A. Blower motor bridge
B. Blower motor wire
A
B
A. Exhaust Port
A
A
B
A. Blower motor wire
B. Connector
A B
A. Screws
B. Recessed holes
A
B
A. Screws
B. Blower motor screw holes
A
A. Damper plate