Haier GDE480BW 6.5 Cu. Ft. Capacity Top-Load Electric Dryer

User Manual - Page 19

For GDE480BW.

PDF File Manual, 98 pages, Download pdf file

Loading ...
Loading ...
Loading ...
17
A1. Remove the green ground screw connecting the neutral-ground jumper wire
(green) to the cabinet and the center terminal block screw, then discard the
jumper wire.
A2. Attach the power cord ground wire (green) to the cabinet with the green ground
screw. Tighten the screw securely.
A3. Attach the power cord neutral wire (white) with the center terminal block screw.
Tighten the screw securely.
A4. Attach the remaining 2 power cord line wires (red and black) with the outer
terminal block screws. Attach one wire to each terminal block as shown. Tighten
both screws securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
PART B - 3-WIRE POWER CORD
A
B
C
E
D
F
Ground Screw (Green)
Terminal Block Screw
Neutral-Ground Jumper Wire
(Green)
Power Cord Neutral Wire (White)
Power Cord Line Wires (One Red;
One Black)
Power Cord
B1. Attach the power cord neutral wire (white) to the center terminal block screw.
Tighten the screw securely.
B2. Attach the remaining 2 power cord line wires (red and black) with the outer
terminal block screws. Attach one wire to each terminal block as shown. Tighten
both screws securely.
IMPORTANT: Do not make a sharp bend or crimp the wires at connections.
STEP 2 - CONNECT TO A GAS SUPPLY LINE
(GAS DRYER ONLY)
NOTE: Do not connect the dryer to an LP gas line without Þ rst converting the
dyer with a conversion kit. An LP conversion kit must be installed by a qualiÞ ed
technician.
NOTE: Apply a pipe-joint compound that that is resistant to the action of LP gas to
all males threads. Do not use plumber’s tape.