Leviton DZ15S Decora Smart Switch

User Manual - Page 2

For DZ15S.

PDF File Manual, 2 pages, Read Online | Download pdf file

DZ15S photo
Loading ...
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try
to correct the interference by one or more of the following measures:
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
WARNINGS AND CAUTIONS
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
To be installed and/or used in accordance with electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
The Decora
®
DZ15S is not compatible with standard 3-way or 4-way switches.
Use only (1) Decora
®
DZ15S switch in a multi-location circuit with up to 9 coordinating remote switches (DD0SR-10), or up to 4 matching remote switches (DD0SR-DL).
Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90m).
WARNINGS AND CAUTIONS
Recommended minimum wall box depth is 2-3/4".
Use this device with copper or copper clad wire only.
Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
Leviton recommends Z-Wave
®
technology in residential installations up to 7,500 sq ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass
through interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.
• Z-Wave
®
networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
3-Way Wiring with DD0SR-10 Coordinating
Remote (no LED) Application:
WARNING: TO AVOID FIRE SHOCK OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Identifying your wiring application
(most common):
NOTE: If the wiring in your wall box does not
resemble any of these configurations, consult
an electrician.
INSTALLING YOUR SWITCH
NOTE: Use check boxes when Steps are completed.
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
Step 1
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
2
5
4
3
1
3-Way
1. Line or Load
(see important instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
Step 2
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal Label:
Use terminal for 3-way or more applications only.
For single-pole applications, DO NOT remove label.
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
2
4
WH
BK
RD
YL/RD
1
3
Single Pole Wiring Application:
Step 4a
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal
screw.
Line Hot wall box wire to terminal screw marked "BK".
Load wall box wire to terminal screw marked "RD".
Line Neutral wall box wire to terminal screw marked "WH".
Switch terminal screw marked "YL/RD" should have Red
insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw
marked "YL/RD", use electrical tape to cover.
Proceed to Step 5.
Leviton’s Decora Smart
TM
Z-Wave
®
Devices are designed to
communicate with each other via Radio Frequency (RF) to provide
remote control of your lighting. In a Z-Wave
®
network, each device
is designed to act as a router. These routers will re-transmit the RF
signal from one device to another until the intended device is reached.
This ensures that the signal is received by its intended device by
routing the signal around obstacles and radio dead spots. This switch
is compatible with any Z-Wave
®
enabled network, regardless of the
manufacturer and can also be used with other devices displaying the
Z-Wave
®
logo.
WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH
DO NOT USE the remote for the control of high power heating
appliances such as portable heaters. There can be some unexpected
consequences if not used with care. For example, an empty coffee pot
can be remotely turned on. If that should happen, your coffee pot could
be damaged from overheating. If an electric heater is turned on by
remote control while clothing is draped over it, a fire could result. This
device will not control lighting that is used with electronic low-voltage
and high frequency power supply transformers, nor high pressure
discharge lamps (HID lighting). This includes mercury-vapor, sodium
vapor and metal halide lamps.
Decora Smart
TM
Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home offices, outdoor lighting or anywhere full control of
lighting is desired.
Z-Wave Plus™ Certification
- Increased communication range
- Network Wide Inclusion
- Support for beaming and secure commands
- Over The Air (OTA) updates
Compatible with Leviton Vizia RF
+
systems
Three way communication
Ease of installation - No new wiring
FEATURES
INTRODUCTION
SwitchCoordinating Remote (no LED)
Terminal
Screw
marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
White (WH)
Terminal
Screw
marked
Yellow/Red
(YL/RD)
2
4
Terminal
Screw marked
Yellow/Red (YL/RD)
2
4
1
WH
BK
RD
YL/RD
WH
BK
RD
YL/RD
1
Neutral to Terminal
Screw marked
White (WH)
3 3
5 5
Terminal
Screw
marked
Black
(BK)
Terminal
Screw
marked
Yellow/Red
(YL/RD)
Green
Ground
Green
Ground
Hot (Black)
Neutral (White)
Coordinating Remote (no LED)
YL/RD
YL/RD
RD
WH
RD
BK
Black
BK
WH
White
Line
120/277VAC
60Hz
(unused)
(unused)
Load
Switch
Step 4b
NOTE: The switch must be installed in a wall box that has a Line Hot and
Neutral connection. The coordinating remote must be installed in a wall
box with a Load connection and a Neutral connection. A Neutral wire to
the coordinating remote needs to be added as shown. If you are unsure
about any part of these instructions, consult an electrician.
NOTE: Maximum wire length from switch to all installed remotes cannot
exceed 300 ft (90 m).
WIRING SWITCH (wall box with line hot connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked "BK".
First Traveler wall box wire to terminal screw marked "RD"
(note wire color).
Remove Red insulating label from terminal screw marked "YL/RD".
Second Traveler wall box wire to terminal screw marked "YL/RD"
(note wire color). This traveler from the switch must go to the
terminal screw on the remote marked "YL/RD".
Line Neutral wall box wire to terminal screw marked "WH".
WIRING COORDINATING REMOTE
(wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are unused.
Tighten both screws.
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).
Second Traveler wall box wire (note color as above) to terminal screw
marked "YL/RD". This traveler from the remote must go to the terminal
screw on the switch marked "YL/RD".
Remove White insulating label from terminal screw marked "WH".
Line Neutral wall box wire to terminal screw marked "WH".
Proceed to Step 5.
TOOLS NEEDED TO INSTALL YOUR SWITCH
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Changing the color of your Switch:
Your switch includes two color options. The switch ships with the White
frame attached. To change color of frame, proceed as follows:
1
2
Insert top
tabs and
press in
bottom
tabs to
attach
Push in
sides at
bottom tabs
and pull
outward to
release
Preparing and connecting wires:
This switch can be wired using side wire terminal screws
or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
IMPORTANT : For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both the
switch wall box and remote wall box.
Step 3
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Coordinating Remote (no LED) Application, go to Step 4b.
For 3-Way Matching Remote (with LED) Application, go to Step 4c.
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Side Wire Connection
Side wire terminals accept
#14-12 AWG solid copper
wire only.
Back Wire Connection
Back wire openings accept
#14-12 AWG solid copper
wire only.
Hot (Black)
Neutral (White)
Load
Switch
BK
Black
White
RD
Green
Ground
YL/RD
Line
120/277VAC,
60Hz
Use terminal for
3-way or more
applications only.
For single-pole
applications,
DO NOT remove label.
WH
3-Way Wiring with DD0SR-DL Matching
Remote (with LED) Application:
Step 4c
SwitchMatching Remote (with LED)
Terminal
Screw
marked
Black
(BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
White (WH)
Terminal
Screw
marked
Yellow/
Red
(YL/RD)
Terminal
Screw marked
Red (RD)
2
3
5
Neutral to Terminal
Screw marked
White (WH)
2
3
5
WH
BK
RD
YL/RD
WH
BK
RD
YL/RD
1
4
4
1
Terminal
Screw
marked
Black
(BK)
Terminal
Screw
marked
Yellow/
Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
YL/RD
YL/RDRD
BK
Black
White
Line
120/277 VAC
60Hz
WH BK
WH
Matching Remote (with LED)
Switch
Green
Ground
Green
Ground
RD
(unused)
NOTE: The switch must be installed in a wall box that has a Load and
Neutral connection. The matching remote must be installed in a wall
box with a Line Hot connection and a Neutral connection. A Neutral
wire to the matching remote needs to be connected as shown. If you
are unsure about any part of these instructions, consult an electrician.
NOTE: Maximum wire length from switch to all installed remotes
cannot exceed 300 ft (90 m).
WIRING MATCHING REMOTE
(wall box with line hot connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: "RD" terminal on matching remote is unused. Tighten screw.
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked BK.
Second Traveler wall box wire from switch to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red switch terminal screw.
Line Neutral wall box to remote terminal screw marked "WH".
WIRING SWITCH (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch to
Red terminal screw.
First Traveler Line Hot to Black terminal screw.
Remove Red insulating label from Yellow/Red terminal screw.
Second Traveler wall box wire (note color as above) to Yellow/Red
terminal screw. This traveler from the switch must go to the terminal
screw on the remote marked "YL/RD".
Line neutral wall box wire to White terminal screw.
Proceed to Step 5.
RATINGS
Incandescent - 1800W - 120VAC, 60Hz
LED/CFL - 5A, 600W - 120VAC, 60Hz
Fluorescent - 15A - 120VAC, 60Hz
8A - 277VAC, 60Hz
Resistive - 15A - 120VAC, 60Hz
Motor - 1/2 HP - 120VAC, 60Hz