Nivona NICR 799 CafeRomatica fully automatic espresso machine

User Manual - Page 26

For NICR 799.

PDF File Manual, 30 pages, Read Online | Download pdf file

NICR 799 photo
Loading ...
Loading ...
Loading ...
26 Solving problems yourself
NOTE
To avoid problems, the following should be
observed:
Always remove the water tank from
the machine to fill it
Do not store coffee beans in the
refrigerator
Always empty containers with the
machine switched on
Use fresh and cooled milk
Problem Cause Remedy
No hot water or
drawing of milk froth /
steam possible
System might need
descaling
Perform high-dosage
descaling (Chapter 8.5.)
Frother is plugged Disassemble frother
completely and clean it
thoroughly
Too little milk froth or
liquid froth
Frother is plugged Disassemble frother
completely and clean it
thoroughly
Unsuitable milk Use cold milk
System might need
descaling
Perform high-dosage
descaling (Chapter 8.5.)
Coffee comes out only
dropwise
System might need
descaling
Perform high-dosage
descaling (Chapter 8.5.)
Grind fineness is too fine /
too coarse
Set grind fineness coarser /
finer (Chapter 7.2.)
Ground coffee is too fine Use coarser ground coffee
Too much ground coffee
added
Add less ground coffee
Brewing unit is plugged Remove and clean brewing unit
(Chapter 8.6.).
Reinsert brewing unit and
perform a system cleaning
(Chapter 8.4.)
Coffee outlets are plugged Perform system cleaning
(Chapter 8.4.)
Loading ...
Loading ...
Loading ...