Viking VRUI5241GSS - 5 Series 24" Stainless Frame Right Hinge Undercounter Refrigerator

Install / Use & Care MANUAL - Page 7

For VRUI5241GSS. Series: 5 SERIES
Also, The document are for others Viking models: VRUI5241, VBUI5151, VBUI5241

PDF File Manual, 18 pages, Read Online | Download pdf file

VRUI5241GSS photo
Loading ...
Loading ...
Loading ...
7
"A"
"B"
"C"
"D"
"E"
PRODUCT DIMENSIONS
ROUGH-IN OPENING DIMENSIONS CABINET DIMENSIONS
MODEL "A" "B" "C" "D" "E" "F" "G" "H" "J"
VBUI515
15"
(38.1 cm)
**34" to 35"
(86.4 to 88.9 cm)
*
14
7
8"
(37.8 cm)
33
3
4" to 34
3
4"
(85.7 to 88.3 cm)
23
23
32"
(60.2 cm)
26
7
32"
(66.6 cm)
37
13
32"
(95 cm)
17
7
16"
(44.3 cm)
VRUI524
VBUI524
24"
(61 cm)
**34" to 35"
(86.4 to 88.9 cm)
*
23
7
8"
(60.7 cm)
33
3
4" to 34
3
4"
(85.7 to 88.3 cm)
23
23
32"
(60.2 cm)
26
7
32"
(66.6 cm)
46
13
32"
(117.9 cm)
26
7
16"
(67.2 cm)
* Depth dimension of rough-in opening may vary depending on each individual installation. To recess entire door "F" di-
mension plus 1" (2.5 cm) for thickness of power cord plug is required.
** Minimum rough-in opening required is to be larger than the adjusted height of the cabinet.
Figure 10
Figure 10a
If necessary to gain clearance inside the rough-in
opening a hole can be cut through the adjacent cabi-
net and the power cord routed through this hole to a
power outlet. Another way to increase the available
opening depth is to recess the power outlet into the
rear wall to gain the thickness of the power cord plug.
Not all recessed outlet boxes will work for this applica-
tion as they are too narrow, but a recessed outlet box
equivalent to Arlington #DVFR1W is recommended
for this application, (see Figure 11).
Figure 11