Note: The garden product will not operate unless both locking
levels are engaged.
Battery Charge-control Indication
The battery is equipped with a charge-control indicator
which indicates its charge condition. The charge-control indi-
cator consists of 3 green LEDs.
Press the button to actuate the charge-control indicator . Af-
ter approx. 5 seconds, the charge-control indicator goes out
automatically.
The charge condition can also be checked when the battery is
removed.
When no LED lights up after actuating the button , the battery
is defective and must be replaced.
For safety reasons, the charge condition of the battery can
only be checked when the garden product is at a standstill.
During the charging procedure, the three green LEDs light up
one after the other and briefly go out. The battery is fully
charged when the three green LEDs light up continuously. The
three LEDs go out again approx. 5 minutes after the battery
has been fully charged.
Temperature Control Indicator
The red LED signals that the battery or the electronics of the
garden product (with battery inserted) are not within the op-
timum temperature range. When this occurs the garden prod-
uct will not operate or not at full capacity.
Temperature Control of the Battery
The red LED flashes when you press the button or the On/Off
switch (with battery inserted): The battery is outside of the
permitted operating temperature range.
The battery switches off at a temperature above 70 °C until
the optimum temperature range is reached again.
Battery Maintenance
Use the following procedures to enable optimum usage of the
battery:
Protect the battery against moisture and water.
Store the battery only within a temperature range between
20 °C and 50 ° C. As an example, do not leave the battery
in the car in summer.
Do not leave the battery in the product in direct sunlight.
The ideal storage condition for the battery is 5 °C.
Occasionally clean the venting slots of the battery using a
soft, clean and dry brush.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
Troubleshooting
LED Indicators Battery Capacity
Continuous lighting of 3 green LEDs 2/3
Continuous lighting of 2 green LEDs 1/3
Continuous lighting of 1 green LED 1/3
Flashing of 1 green LED Reserve
Problem Possible Cause Corrective Action
Hedgecutter does not operate Battery discharged Recharge battery; also see “Battery
Charging”
Battery not fully connected Ensure both locking levels are engaged
Hedgecutter operates intermittently Internal wiring of machine damagedContact Service Agent
On/Off switch defectiveContact Service Agent
Motor reverses repeatedly then stops
after 3 s.
see “Working Advice” (Anti Blocking)
Motor runs but blades remain stationary Internal fault Contact Service Agent
Cutting blade hot Cutting blade blunt Have blade sharpened
Cutting blade has dents Have blade inspected/overhauled
Too much friction, due to lack of lubricant Apply lubricant spray
Blade will not move Battery discharged Recharge battery; also see “Battery
Charging”
Machine defective Contact Service Agent
Excessive vibrations/noise Machine defective Contact Service Agent