User Manual - Page 2

For BH55500PCCK. Also, The document are for others Hoover models: BH55500*, BH55500PC*

Loading ...
NORMAL
WARNING:
Risk of personal injury
- Brush roll may suddenly restart. Turn
power switch off and remove battery before
cleaning or servicing.
WARNING:
Risk of personal injury
- Brush roll may suddenly restart. Turn
power switch off and remove battery before
cleaning or servicing.
WARNING:
To reduce the risk of
injury from moving parts - remove battery
before cleaning or servicing.
1
1
1
3
2
2
2
4
5
3
4
Remove the two black screws, then remove
bottom plate.
Lay the unit flat to access the power head
nozzle. Remove the 7 screws to take o the
baseplate from the power head.
An overloaded filtration bag may cause
dirt and debris to back up into the air flow
system. Open the bag dock and check for
visible clogs at the bag port. Change filtration
bag if contents have reached the MAXIMUM
FILL LINE.
If blockage is not in the power head
nozzle, remove the lower tube. Detach rubber
straps at bottom of bag and remove screws to
tilt battery dock forward.
Lift up metal guards to access the brushroll
channel.
Remove the brushroll belt and brushroll from
the holding channels inside of the power
head nozzle.
Also, check for blockages in the power head
nozzle.
Twist lower tube connector counterclockwise
and slide up. Pull the lower tube out of the fan
housing. Once removed, check for blockage.
If the lower tube is not blocked, look into
the fan housing for blockage. Be sure to
reassemble lower tube and tighten the lower
tube connector before continuing use.
Clear brushroll of debris and obstructions by
using scissors to cut across the channel.
Put metal guards back into place and secure
wiper back into place with the two black
screws.
QUICK ACCESS
BRUSH ROLL CLEANING
REMOVING THE BRUSH ROLL AND BELT CLEARING CLOGS
(A)
(A)
(B)
NOTES: Batteries are shipped in a low
charge condition to prevent possible
problems. You should charge them before
first use. If the light on the charger flashes
red, there is an error with the battery or
the charger. Try again or call customer
service for support at 1-800-406-2005.
CHARGING AMBIENT TEMPERATURE RANGE:
5 °C – 40 °C (41 °F – 104 °F).
Fully assemble product prior to use.
TROUBLESHOOTING
ACCESSORIES
FIND AVAILABLE REPLACEMENT PARTS AND ACCESSORIES AT HOOVER.COM.
IF APPLIANCE IS NOT WORKING AS IT SHOULD, HAS BEEN DROPPED, DAMAGED, LEFT OUTDOORS, OR
DROPPED INTO WATER, CALL CUSTOMER SERVICE AT 1-800-406-2005 PRIOR TO CONTINUING USE.
GENUINE PARTS AND ACCESSORIES: We recommend using only with genuine HOOVER® replacement
bags (for Hoover bagged uprights), parts, and accessories. Damage caused by use with other than
genuine HOOVER® bags, parts, and accessories is not covered by and may void your warranty.
CHARGING
THE BAT TERY
GETTING STARTED
HOW TO INSERT
THE BAT TERY
1
2
3
4
1
3
To charge, align the battery to the charger and
slide into place.
Make sure the filtration bag (A) is attached
properly to the bag dock (B).
Instructions can be found on the bag and in
the maintenance section of this manual.
Step on power head (A) to lower the handle.
NOTE: The auto lock feature will disengage motor
when vacuum is upright.
Push power switch to change between Hard
Floor, Carpet and Power OFF modes.
To insert the battery, align the grooves and
slide battery until it clicks into place.
To remove, press the latches and slide the
battery out.
Press the latches and pull to remove.
2
When your battery is charging the lights on
the charger will blink. Once charge is com-
plete, lights on the battery will turn o.
Rotate both plastic black endcaps at the
ends of the brushroll to show a single notch
“NORMAL” position. Insert back into the
holding channels of the power head nozzle.
NOTE: Ensure both end cap settings are the same
facing up when replacing the brush roll.
Reassemble the brushroll belt.
Manually spin the brushroll to see that it
turns freely.
Replace the 7 screws to secure the baseplate
to the power head nozzle.
3
4
5
6
HOW TO USE (CONT’D)
(A)
MAINTENANCE
2
3
4
Gently pull the cardboard collar on the filtra-
tion bag up to engage the self sealing lock
and remove from the bag dock. Discard.
Slide a new filtration bag collar firmly into the
bag dock ensuring all hooks on dock door are
inserted on the cardboard collar.
Rotate bag dock up and press firmly on the
filtration bag at indicated points until it snaps
into place.
HOW TO REPLACE THE FILTER BAG
(CONTD)
(A)
(C)
(B)
GETTING STARTED
1
Insert Upper Tube Connector (A) into top of
Debris Transfer Tube (C). Twist Upper Tube
Connector until it clicks to secure Upper
Tube (B).
HOW TO USE
Fully assemble product prior to use.
NOTE: Do not operate without a bag.
WARNING:
To reduce the risk of
personal injury, remove battery before
cleaning or servicing. Do not use vacuum
bag without filtration bag in place.
WARNING:
Very fine materials,
such as face powder or cornstarch may seal
the filtration bag and cause it to burst even
though it is only partially full. Change the
bag often when cleaning this type of
material.
MAINTENANCE
1
Unzip the Filtration Bag Case and Pull the
cardboard collar downward to release the bag
dock from the port.
Find available replacement parts and accessories
at Hoover.com.
If appliance is not working as it should, has been
dropped, damaged, left outdoors, or dropped into
water, call customer service at 1.800.406.9005 prior
to continuing use.
HOW TO REPLACE THE FILTER BAG
FILTER BAG MODEL #AH15600
LUBRICATION: The motor and brush roll
are equipped with bearings which contain
sufficient lubrication for their lifetime.
The addition of lubricant could cause
damage. Do not add lubricant to motor or
brush roll.
THE BELT: This vacuum is equipped with
the fiber reinforced stretch belt, which
is designed for long life and doesn’t need
changing.
MOTOR PROTECTIONS: If the vacuum becomes
overloaded (which could occur when a large
obstruction is sucked up or when vacuuming
extremely thick carpet), the electronics are
designed to shut down the vacuum. If this happens,
the vacuum will automatically shut o. To reset the
vacuum, turn the unit to “O” or o, then turn on to
continue use. If it shuts down again there may be a
large obstruction in the vacuum. See Clearing Clogs
for the steps on clearing a clog from the air path.
FILTER BAG
MODEL
#AH15600
Loading ...
Loading ...
Loading ...