Inline Fan Instructions
1. Overview
The iPower Inline Fan, an addition to the iPower family, utilizes the newest and advanced
technology to offer an affordable air movement solution. The iPower Inline Fan features
high efficiency centrifugal impeller and a high performance external rotor motor. The
compact, lightweight, and powerful motor generates high rate of air flow with minimal
vibration and noise, which prolongs the inline fans service life. Its versatile and compact
design allows easy and flexible installation. Not just used in indoor gardens and
greenhouses, the iPower inline fan can be found in hotels, halls, meeting rooms,
supermarkets, railway stations, airports and other public areas that require positive
ventilation.
2. Product Structure
a) The iPower Inline Fan is composed of the chassis, impeller, external rotor motor, and junction box.
b) Chassis: Is made of a high-quality, cold-rolled steel. The surface is treated with a plastic sealant to
provide a strong resistance to corrosion. CAD optimizations on the flow channel design to allow
the impeller perform at its greatest efficiency. Inlet and outlet diameter flanges are easy to install,
repair and clean. Specifications: φ100mm, φ125mm, φ150mm, φ160mm, φ200mm, φ250mm,
φ315mm.
c) Impeller: diameter φ190mm, φ220mm, φ250mm. The curved-end blade impeller works with the
fan casing in harmony; the fan can produce maximum air flow and efficiency while minimizing
noise.
d) External Rotor Motor: A single-phase asynchronous external rotor motor is located on the chassis.
The impeller is attached directly to the rotor motor by die-casting. The impeller is driven directly
by rotor to minimize noise while providing high airflow and extending service life.
e) Junction box: The flame-retardant ABS plastic provides fireproof performance and is safe to use.
The external location of the junction box allows for easy service and removal.
background
2
3. Dimensions:
A---Air outlet and inlet diameter B---Cylindrical chasse diameter of
C---The length of a draft D---The total length of chasse
E---Length of air inlet
4. Operating Parameters
5. Schematic wiring diagram
Single-speed centrifugal Circu
l
ar Duct Fan wiring diagram
motor
hull
junction box
C E
D
ΦA
ΦA
ΦB
air
outlet
air
intake
mount
GLFANXINLINEEVO4
1
90
Specification(mm)Model ΦA
98
2
72
ΦB
C
20
D
190
E
21
Model
70
(W)
Power
Input
182
60
GLFANXINLINEEVO4
2750 65
F
490
2.8
(Kg)
Weigh
et
(pa
)
Static
(dB)
Nois
e
(rpm)
Spee
d
(CFM)
Airvelocit
y
(Hz)
Frequenc
y
110
(V)
Voltag
e
class
Insulatio
n
background
3
6. Installation & Troubleshooting
Mount the fan on a stable platform via mounting brackets.
Slide the mounting clamps over air duct
Slide the air duct onto the flanges on the fan
Tighten the clamps down with a flat-head screwdriver or a hex socket.
Plug the 110V plug into a wall outlet to turn on the fan.
If the product had been in storage for more than six months, insulation resistance
must be tested before use. Resistance to ground should be 20MΩ or more. Before
starting the fan, use hands to drive impeller to insure smooth impeller rotation without
obstruction. After connecting the power, observe the impeller rotation direction to be in the
same direction with the nameplate. After confirming everything is functioning properly,
leave it running for half an hour (30 minutes) to test the whether motor will have issues
with overheating or undesirable noises. If the fan does not exhibit any signs of abnormal
operations, it is safe to use and install.
To extend fan life, it is recommended that air filters and one-way valves be installed
on the fans inlet and outlet.
The circular fan must only be used indoors and be mounted with non-adhesive
materials. Keep fan clean from dust and foreign contaminants. Both ends of the fan must
be connected to the pipeline.
7. Repairs and Maintenance Notes
Under normal operating conditions, the fan should be cleaned every six months.
Clean any dirt that may have accumulated inside the chassis and dust on the impeller, etc.
Do not use water or any other liquid cleaning agent; use only a clean brush or a clean dry
cloth to wipe away any loose dirt or dust. Proper cleaning ensures the fan operates at
maximum efficiency against the impact of dust without impacting air flow. If it is used in
environments that contain heavy dust, cleaning should occur more often to prevent the
accumulation of dust that would impact normal operations.
Disassembly of the fan is extremely convenient.
Remove the metal clamps from the flanges
Remove the duct from the fan
Dismount the fan from the mounting surface
Remove the four screws that holds the fan housing
Remove the junction box screw
Remove 4 screws from the mounting bracket.
background
4
8. Warning
Please read this manual carefully before installing.
The fans motor power is multiplied by the shaft power factor of the specific
operating conditions. In order to prevent electrical overload, please DO NOT
obstruct the inlet or outlet airflow as the motor is running.
Avoid impact or physical damage of the unit as it will cause premature failure.
Keep fan in a dry environment.
In the transmission of air, or any other non-corrosive medium, inlet temperature
must not exceed 80C. The amount of dust and other solid contaminant should not
exceed 100g per cubic meter. Avoid viscosity and fiber material.
This product is covered under 12 month manufacturer’s warranty.

Specifications

Indexed Terms: Duct Inline Fan

IPower 4 INCH 190 CFM DUCT INLINE FAN Questions and Answers


#1 Will this work with a 18" 3 speed floor fan. that runs no more than 4 hrs or less at a time?

Irregardless of the type of fan, as long as it runs on standard 110Volt it should work. I am using it on me ceiling’s fan which plugs right into a 110V socket. I got it so I can control my 3speed fan more precisely. Works well for me.

#2 Would this be able to control the speed on an angle grinder?

Definitely not. This controller is made to control the speed of low current exhaust fans.

#3 Is there a cleanable dust filter that will fit the input side?

You would have to fabricate a filter holder or jerry rig a filter from heavy equipment to fit. A lot of large Cat or truck filters would be a good start.