Hestan KRT304NGBG 30 Inch Gas Rangetop with 4 Sealed Burners

User Manual - Page 8

For KRT304NGBG.

PDF File Manual, 28 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
©2019 Hestan Commercial Corporation
6
EN
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
W
9-1/2”
[24.1]
2”
[5.1]
V
12”
[30.5]
28-1/2”
[72.4]
10”
[25.4]
7-1/2” [19] MAX.
OPENING
HEIGHT
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
G
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
E
PLATFORM
COMBUSTIBLE
MATERIALS
INSTALLATION CLEARANCES WITH ISLAND TRIM
FRONT VIEW
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
COMBUSTIBLE
MATERIALS
12”
[30.5]
28-1/2”
[72.4]
24-1/2” [62] MAX.
PLATFORM
7-1/2” [19]
MAX.
OPENING
HEIGHT
[71.6]
37-1/8”
[94.3]
TO COOKING
SURFACE
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
COOKING
SURFACE
APPLIANCE
TOP
SIDE VIEW
28-3/16”
FRONT COOLING VENTS
NOTICE
When placing your rangetop in the cabinet, DO NOT
BLOCK or obstruct the front cooling vents shown.
These vents allow air into the appliance to keep the
internal electronic parts cool.
COOLING
VENTS
RANGETOP
MODEL
W
V (MIN)
KRT304 30” [76.2] 30” [76.2]
KRT365 36” [91.4] 30” [76.2]
KRT364GD 36” [91.4] 30” [76.2]
KRT485GD 48” [121.9] 30” [76.2]
KRT484GD 48” [121.9] 30” [76.2]
NOTES:
*
SHADED AREAS INDICATE WHERE COMBUSTIBLE
MATERIALS ARE NOT ALLOWED.
*
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
*
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT
SHUT-OFF VALVE AS HIGH AS
POSSIBLE IN THIS ZONE
FOR EASY ACCESS WHEN RANGETOP IS INSTALLED.
*
"E" IS ELECTRICAL SUPPLY ZONE.
*
"W" IS APPLIANCE OPENING.
*
"V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
Loading ...
Loading ...
Loading ...