TABLE 2
Burner Gas INPUT
RATE
[Btu/h]
ORIFICE
SIZE
(1/100) mm
SIMMER
RATE
[Btu/h]
PRIMARY
AIR
OPENING
BY-PASS
ORIFICE
SIZE
(1/100)mm
SR NATURAL (A) 7000 120 2100 Open Adj.*
R NATURAL (A) 10500 145 3200 Open Adj.*
Fish Kettle NATURAL (A) 10500 145 3600 Open Adj.*
TC NATURAL (A) 15500 180 5600 Open Adj.*
Dual NATURAL (A) 15500 165+68 8000
15 (external)
/ Open (inner
ring)
Adj.*
Dual (aux only) NATURAL (A) 2300 68 1100 Open Adj.*
Griddle NATURAL (A) 10500 145 3600 Adj.*
Big Solid Top Bur-
ner
NATURAL (A) 8500 130 2100 5 Adj.*
Small Solid Top Bur-
ner
NATURAL (A) 8500 130 2100 5 Adj.*
OVEN (60) NATURAL (A) 11500 155 4
GRILL (60) NATURAL (A) 9000 140 /
OVEN (70) NATURAL (A) 15000 180 4
GRILL (70) NATURAL (A) 13500 165 /
OVEN (90) 1 burner NATURAL (A) 15000 180 /
GRILL (90) NATURAL (A) 13500 165 /
SR LP (E) 7000 78 2100 Open 45
R LP (E) 10500 95 3200 Open 55
Fish Kettle LP (E) 10500 95 3600 Open 60
TC LP (E) 15500 117 5600 Open 75
Griddle LP (E) 10500 95 3600 60
Dual LP (E) 15500 110+43 8000 Open 75
Dual (aux only) LP (E) 2300 43 1100 Open 35
Big Solid Top Bur-
ner
LP (E) 8500 85 2100 5 45
Small Solid Top Burner
LP (E) 8500 85 2100 5 45
OVEN (60) LP (E) 11500 95 2800 20 55
GRILL (60) LP (E) 9000 88 /
OVEN (70) LP (E) 15000 115 20
GRILL (70) LP (E) 13500 105 /
OVEN (90) 1 burner LP (E) 15000 115
/
GRILL (90) LP (E) 13500 105 /