Braeburn 505 Builder Model Thermostat

User Manual - Page 3

For 505.

PDF File Manual, 3 pages, Read Online | Download pdf file

505 photo
Loading ...
Loading ...
4
©2013 Braeburn Systems LLC • All Rights Reserved. 500-100-04
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Phone: 866-268-5599
When installed by a professional contractor, this product is backed by a 1 year limited warranty. Limitations apply. For limitations,
terms and conditions, you may obtain a full copy of this warranty:
· Visit us online: www.braeburnonline.com/warranty
· Phone us: 866.268.5599
· Write us: Braeburn Systems LLC
2215 Cornell Avenue
Montgomery, IL 60538
WIRING DIAGRAMS
6
Typical 4-Wire Single Transformer Heating and Cooling System
O G W
Factory Installed
Jumper
Y
BRc Rh
Cool
Control
Heat
Control
120
Volt AC
Hot Side Transformer
24 Volt AC
Transformer
Fan
Control
Typical 5-Wire Two Transformer Heating and Cooling System
O G W
Remove
Factory Installed
Jumper
YBRc Rh
Cool 24 VAC
Transformer
120
Volt AC
Heat 24 VAC
Transformer
120
Volt AC
Hot Side Cool
Transformer
Heat
Control
Fan
Control
Cool
Control
Hot Side Heat
Transformer
Typical Single Stage Heat Pump Reversing Valve Active in Cooling
O G W
Factory Installed
Jumper
Y
BRc Rh
24 Volt AC
Transformer
120
Volt AC
Hot Side Transformer
Fan
Control
See Note 1
NOTES: 1. For Model 505 with Electric Heat, if fan wire is present connect to “W” terminal.
2. For 2-Wire 24 Volt AC or 250mV – 750mV Millivolt Heating Only Systems, remove factory installed jumper.
cont.
WIRING DIAGRAMS
6
NOTES: 1. Installer must place jumper wire between “W” and “Y” terminals.
2. For Typical Single Stage Heat Pump Reversing Valve Active in Heating, reversing valve
must be connected to “B” terminal instead of “O” terminal.
ONE YEAR LIMITED WARRANTY
Compressor
Control
Reversing
Valve